Use this appliance only as described in this instruction manual.
As with any electrical appliance, whilst the instructions aim to cover as
many eventualities as possible caution and common sense should be
applied when operating and installing this air conditioner.

This appliance has been manufactured to cool and de-humidify
domestic environments and should not be used for other purposes.

It is dangerous to alter or modify the unit's characteristics in any way.

The appliance must be installed in line with the relevant national legi-
slation.

Should repairs be necessary, contact Parex Industries Ltd for your nea-
rest authorised De’ Longhi Service Agent. Unauthorised servicing can
be dangerous.

This appliance is to be used by adults only; keep away from children.

In the case that the power cable becomes damaged, this must be sub-
stituted only by specialised personnel authorised by the manufacturer.

Always ensure the appliance is earthed. If you have any doubts check
with a qualified electrician.

Avoid using extension leads with the unit.

Before cleaning or maintenance operations, always unplug the unit
from the socket.

Do not pull on or place strain on the power cable when moving the
appliance.

The appliance should not be installed where the atmosphere may
contain combustible gases, oil or sulphur, or near heat sources.

Do not rest hot or heavy objects onto the appliance.

Remember to perform the descaling procedure at the end of each
season (see page 13).  In areas where the water is particularly hard
(rich in minerals), the use of a commercial anti-lime product added to
the water is recommended.  This can be requested from Parex Indu-
stries Ltd.

Clean the filters at least once a week.

Avoid using heaters near the unit.

The unit should be transported in a vertical position. If this is not
possible secure the unit at an angle, do not lie horizontally.

Before transporting the unit drain the condensation collecting-tray
and tank. After transportation, wait at least 1 hour before switching on
the unit.

The packaging materials can be recycled. You are therefore recom-
mended to place them in the special containers for differentiated
waste collection.

Содержание Pinguino PAC60

Страница 1: ...PAC 60 PAC 60 Use and maintenance manual...

Страница 2: ...erience all around the world we are constantly improving the quality and performance of Pinguino We are confident that you will be satisfied with your purchase and enjoy the cool comfort created by th...

Страница 3: ...Description 9 10 12 14 15 17 16 18 13 19 20 11 21 CONTROL PANEL 22 24 25 23 26 ACCESSORIES 1 2 3 4 5 6 7 8 27 28...

Страница 4: ...check with a qualified electrician Avoid using extension leads with the unit Before cleaning or maintenance operations always unplug the unit from the socket Do not pull on or place strain on the pow...

Страница 5: ...oved from one room to another in the home or even transferred between different buildings The hot air in your room is passed through a coil cooled by refrigerant gas removing excess heat and moistu re...

Страница 6: ...e unit near a window French win dow or door Open the window French window or door slightly and place the window attachment as shown in figure B 24 23 24 Setting up B C 1 2 A For optimum results If you...

Страница 7: ...Make a hole in a outside wall or through the glass of a window Check the height and dimensions given in figure D 30 cm 30 cm 106 MAX 120 cm MIN 30 cm When the hose is not attached close the hole with...

Страница 8: ...cooling power 23 5 A To open the front panel grip either side of the panel and gently pull the panel towards you and upwards Remove the tank Lifting it forward 5 3 B Turn the tank upside down and rem...

Страница 9: ...ollowing the direction of the arrow until the number 16 is lined up with the triangular pointer the arrows indicates 4 00 P M approximately 12 21 20 19 1 6 pointer N B Never turn the dial in an anti c...

Страница 10: ...or on initial start up 2 You may also experience a slight delay between changing from one function to another 15 14 21 19 15 21 14 21 18 9 10 TURBO POWER The Turbo Power mode was designed to pro vide...

Страница 11: ...linds or draw the curtains do not cover Make sure the unit is located on a level floor If necessary place the two blocking devices under the front wheels 26 Do not rest objects on the air conditioning...

Страница 12: ...t part Alternatively the dust filter included with the appliance may be used in place of the purification filter CLEANING THE RESERVOIR It is recommended that you clean this at least once a month usin...

Страница 13: ...he air conditioner for about half an hour 4 After this drain out all of the liquid remai ning in the collection reservoir and rinse thoroughly During the rinsing process the drainage hose must be open...

Страница 14: ...hermostat adjusted too high air filters clogged the output of the unit is insufficient for the con ditions or size of the room wait three minutes safety devi ce before the appliance start cooling clos...

Страница 15: ...370 m3 h Dimensions width 580 mm height 785 mm depth 435 mm RECOMMENDED OPERATING CONDITIONS Room temperature 21 32 C This appliance contains substances which if released into the atmosphere would da...

Страница 16: ...D e L o n g h i S p A V i a L S e i t z 4 7 3 1 1 0 0 Tr e v i s o I t a l i a t e l 3 9 0 4 2 2 4 1 3 1 f a x 3 9 0 4 2 2 4 1 3 6 4 7 w w w d e l o n g h i c o m 5751008600 06 02...

Отзывы: