background image

10

F i n a l   c h e c k

-

Doors and windows of  room to be air con-
ditioned are closed (with the exception of
temporary installation where a partially
opened window is necessary).

-

Shade the room as far as possible from
direct sunlight by drawing curtains
and/or lowering blinds or shutters, for
economical and efficient air-cooling.

-

Ensure that intake and outlet vents (fig. 2
and 3) are not blocked.

-

Make sure there are no sources of heat in
the room.

In order to obtain maximum performance from your air conditioner make sure that:

fig. 13

fig. 14

SPECIAL NOTE

This machine is designed to be used with or without water. Maximum performance is obtained
using water. 

HOW TO PREPARE WATER CONTAINER

Use only clean, salt-free tap water. The water is essential for the air cooling operation and is
discharged in the form of steam through the exhaust outlet. A container full of water lasts for a
period that depends on a number of conditions; such as temperature, humidity, insulation, sun
exposure to the room, number of people present, etc. On average it will last approximately 7 to
10 hours.
When the container is empty, the appliance automatically changes function from water to air. At
the same time, the quantity of air discharged from the rear hose will increase.

Open the water container compart-
ment door, tip the container forwards
and lift up to remove.

Remove the cap, pull out the extenda-
ble tube and fill the container, standing
it on the floor.

After filling, replace the extendable tube,
screw the cap on tightly and return the
container to its place, making sure the
word FRONT is facing out.

During “water condensation” cooling function and in particularly quiet surroundings (eg.
bedroom), a slight gurgling noise may be heard. This is perfectly normal.

Warning:

Do not use water containing salt, eg. seawater or water treated using softening systems
that utilize table salt.

fig. 17

fig. 15

fig. 16

pac360U OK GB  24-04-2003  16:32  Pagina 10

Содержание PAC 360

Страница 1: ...for other than the intended use Do not place any strain on the power cord Avoid twisting and or tangling Ensure that outlet vent of exhaust hose is kept debris clear and obstruction free Ensure that...

Страница 2: ...and congratulate you on your wise choice For optimal results please read this manual carefully before installing or operating We know that the Pinguino will keep your environment pleasingly comfortabl...

Страница 3: ...cy Hz Cooling capacity With water Btu Current consumption A Room thermostat Dimensions width in height in depth in Net weight lbs Refrigerant system freon Compressor protection Freon charge lb gr OPTI...

Страница 4: ...compartment Power cord compartment Manual reset button Castors Castor stops Water collecting tray Water container compartment door Control panel Water container Programmer timer Handle Drainage tube D...

Страница 5: ...ust hose 1 Permanent wall vent 1 Caster stop 2 Descaling fluid 1 Window nozzle 1 Suction disc 2 ACCESSORY CHECK Check that all parts listed in Table are included Window bracket door bracket 1 Electros...

Страница 6: ...leave a door open approx 1 2 inch is enough The unit can also be used as a temporary installation for use in any room with a window or french window this temporary installation can be used at any tim...

Страница 7: ...hole of the bracket so to allow a correct installation of the exhaust hose see the following instructions PREPARING THE UNIT FOR USE 1 Fit the exhaust tube in place if your conditioner is supplied wit...

Страница 8: ...nut it s possible to use the window bracket also for sliding windows Position the hole of the bracket to allow for correction instal lation of the exhaust hose see the following instructions Setting...

Страница 9: ...ater lasts for a period that depends on a number of conditions such as temperature humidity insulation sun exposure to the room number of people present etc On average it will last approximately 7 to...

Страница 10: ...hes on the dial corresponding to the period required each notch represents 15 min 3 Check that the timer indicates the correct time see instructions on setting 4 Select the desired function as shown i...

Страница 11: ...evious page Select the fan speed required pres sing Fan speed key C Key A ON OFF must be released Turn the thermostat to Max Cold COOLEST Pos Press key A ON OFF ON OFF signal light conditioning will c...

Страница 12: ...talla tion procedure Check for any defects in power cord and plug CLEANING OF COLLECTING TRAY 4 Remove plug from drainage tube loca ted at rear of applian ce and empty water 5 When draining is fini sh...

Страница 13: ...lean filter and dry well before replacing 7 Cover appliance with a polyethylene bag to prevent dust from entering You can use the polyethylene bag inclu ded in the packaging Remove dust with a vacuum...

Страница 14: ...case of malfunction turn off and disconnect the Pinguino from power outlet and contact a D Longhi Service Center for qualified assistance toll free number 1 800 322 3848 for U S or 1 888 335 6644 for...

Страница 15: ...write to De Longhi America Inc Park 80 West Plaza One 4th floor Saddle Brook NJ 07663 or call Service Tel No 1 800 322 3848 GARANTIE Nous garantissons que tous les appareils lectriques DE LONGHI sont...

Отзывы: