Tempory installation

Note:

In both cases (permanent and temporary installations) make sure that the Pinguino is posi-
tioned on level ground. If necessary, use the two caster stops for the front casters

This installation makes it easy to
use Pinguino in any room, provi-
ded there is a window or a door: it
allows you to use the Pinguino
immediately (Fig. 5).

Suction cups  may be used to
keep window or door closed  (Fig.
6).

Pinguino is equipped with an adju-
stable window bracket. If you have
a sliding window, place the bracket
on the window sill, extend the
bracket fully within the window
frame and lower the window onto
the bracket. Insert the nozzle of the
exhaust hose into the slot, then con-
nect the hose to the air conditioner
(Fig. 7). With the wing nut, it’s possi-
ble to use the window bracket also
for sliding windows. Position the hole
of the bracket so to allow a correct
installation of the exhaust hose (see
the following instructions).

PREPARING THE UNIT FOR USE

1) Fit the exhaust tube in place; if your conditioner is

supplied with a extendable tube, it is fitted as illu-
strated in the diagram.

2) For permanent installation, place the appliance

near the wall or window outlet. Make sure it is stan-
ding on a level surface and fit the special shock
absorbers/castor stops underneath the castors.

1) Water collects at this point

2) Bend this section

3) Bend this section

NO

YES

YES

ELECTRICAL CONNECTION

Check that the power supply voltage is 115 V ~ 60 Hz.

Important:

If you need to use an extension cord, please be sure to
use a 

heavy duty

extension cord (minimum 14 gauge).

Before connecting the Pinguino to a power supply, make sure
that all switches on the front control panel are in the OFF position.
Connect power cord found in storage compartment at rear of
the Pinguino (Fig. 9).

fig. 5

fig. 6

fig. 7

fig. 8

fig. 9

window
bracket

pac360U OK GB  24-04-2003  16:32  Pagina 8

Содержание PAC 360

Страница 1: ...for other than the intended use Do not place any strain on the power cord Avoid twisting and or tangling Ensure that outlet vent of exhaust hose is kept debris clear and obstruction free Ensure that...

Страница 2: ...and congratulate you on your wise choice For optimal results please read this manual carefully before installing or operating We know that the Pinguino will keep your environment pleasingly comfortabl...

Страница 3: ...cy Hz Cooling capacity With water Btu Current consumption A Room thermostat Dimensions width in height in depth in Net weight lbs Refrigerant system freon Compressor protection Freon charge lb gr OPTI...

Страница 4: ...compartment Power cord compartment Manual reset button Castors Castor stops Water collecting tray Water container compartment door Control panel Water container Programmer timer Handle Drainage tube D...

Страница 5: ...ust hose 1 Permanent wall vent 1 Caster stop 2 Descaling fluid 1 Window nozzle 1 Suction disc 2 ACCESSORY CHECK Check that all parts listed in Table are included Window bracket door bracket 1 Electros...

Страница 6: ...leave a door open approx 1 2 inch is enough The unit can also be used as a temporary installation for use in any room with a window or french window this temporary installation can be used at any tim...

Страница 7: ...hole of the bracket so to allow a correct installation of the exhaust hose see the following instructions PREPARING THE UNIT FOR USE 1 Fit the exhaust tube in place if your conditioner is supplied wit...

Страница 8: ...nut it s possible to use the window bracket also for sliding windows Position the hole of the bracket to allow for correction instal lation of the exhaust hose see the following instructions Setting...

Страница 9: ...ater lasts for a period that depends on a number of conditions such as temperature humidity insulation sun exposure to the room number of people present etc On average it will last approximately 7 to...

Страница 10: ...hes on the dial corresponding to the period required each notch represents 15 min 3 Check that the timer indicates the correct time see instructions on setting 4 Select the desired function as shown i...

Страница 11: ...evious page Select the fan speed required pres sing Fan speed key C Key A ON OFF must be released Turn the thermostat to Max Cold COOLEST Pos Press key A ON OFF ON OFF signal light conditioning will c...

Страница 12: ...talla tion procedure Check for any defects in power cord and plug CLEANING OF COLLECTING TRAY 4 Remove plug from drainage tube loca ted at rear of applian ce and empty water 5 When draining is fini sh...

Страница 13: ...lean filter and dry well before replacing 7 Cover appliance with a polyethylene bag to prevent dust from entering You can use the polyethylene bag inclu ded in the packaging Remove dust with a vacuum...

Страница 14: ...case of malfunction turn off and disconnect the Pinguino from power outlet and contact a D Longhi Service Center for qualified assistance toll free number 1 800 322 3848 for U S or 1 888 335 6644 for...

Страница 15: ...write to De Longhi America Inc Park 80 West Plaza One 4th floor Saddle Brook NJ 07663 or call Service Tel No 1 800 322 3848 GARANTIE Nous garantissons que tous les appareils lectriques DE LONGHI sont...