REFRIGERANT CIRCUITS

Cooling

Heating/Cooling

HEATING

COOLING

Legend

Condenser

coil

Throttling part (capillary)

Quick coupling

General filter

Compressor

Reversing

valve

Check valve

Cooler coil

INDOOR UNIT MULTIFILAR  WIRING DIAGRAM

LEGEND
A1

= Unit 

power 

card

A2

=

Infrared receiver and leds card

A3

=

EMC noise filter

BT1

= Room 

temperature 

sensor

BT2 

=  Exchanger temperature sensor

KA1

= Compressor 

relay

M1

=

Indoor fan motor

M2

=  Stepping motor for flap

SB1

=

Manual operation key

TC1

=

Transformer for card power supply

XP1-XS1 =

Transformer power supply connector

XS2-XP2 =

Motor M1 power supply connector

XS3

=

Quick connector

XT1

=  Power supply terminal board

A

I

A

I

FLAPS

ID1

ID2

12VAC

SW

IR

HALL

ST2  ST1

BLACK

WHITE

RED

BLUE

PINK

YELLOW

ORANGE

RED

1 2 3 4 5 6

RED

GREEN

YELLOW

BLUE VIOLET VIOLET VIOLET VIOLET VIOLET

BLUE

VIOLET

VIOLET

VIOLET

VIOLET

VIOLET

BLACK
BLACK

BLUE

WHITE
WHITE

3

2

1

1 2 3

1

2

3

4

5

6

7

8

9

BLUE

VIOLET

BLUE

VIOLET

BLUE

BLACK

BLACK

M2

TC1

A2

SB1

A1

BT2

BT1

WHITE

WHITE

M1

KA1

AUX 1
4 WAY
IN  F
OUT F
L

L
L

L-FUS

PUMP

XT1

N

3

2

1

3 2 1

1

2

3

BLUE

BLACK

BROWN

XP2

XS2

XS1

XP1

(1) BLUE

(3) BROWN

(2) BLACK

LINE

C

PT

+5V

OUT

SENSOR

RED

WHITE

BLACK

HALL

FAN MOTOR

POWER SUPPLY

1

3

2

4

A3

YE-GR

BROWN

BLUE

YE-GR

RED

BROWN

ORANGE

BLACK

BROWN

BLACK

BROWN

BROWN

BLUE
BLUE

BLUE

YE-GR

XS3

Содержание CF-CP 30 ARE 290

Страница 1: ...aordinary maintenance 35 User diagnostics 36 U I A U I A U I A 70 C A I U The following symbols have been used in some parts of this booklet and inside the appliance User Installer After sales service...

Страница 2: ...cubic metres The CP30 CF30 ARE 290 air conditioner must be used and stored in rooms with a volume of over 53 cubic metres The CF40 ARE 290 air conditioner must be used and stored in rooms with a volu...

Страница 3: ...r suitable absorbent material Prevent the liquid from entering into drains sewers cellars or work holes since the vapors could create a suffocating atmosphere First aid measures Inhalation Remove the...

Страница 4: ...ove the packing only when the air conditioner has been located in the point of installation Carefully remove the adhesive strips positioned on the air conditioner Packaging components must be disposed...

Страница 5: ...ONNECTION OFTHE UNIT I QUICK CONNECTOR I BASIC OPERATION The fast connector coupling uses a retractable sleeve and stem valve on the female half and a spring loaded poppet on the male side to create a...

Страница 6: ...he handle bottoms on the coupling body and the locking pin on models equipped with spring loaded locking pins pops into the handle hole properly see Figure 4 Connect the auxiliary electrical and conde...

Страница 7: ...couplings connected even when the system is not in use in order to minimize refrigerant effusion coupling damage and the entry of dirt or other foreign material If it is not possible to keep the coup...

Страница 8: ...a micropro cessor card 1 Wall mounting plate 2 Indoor unit base 3 Indoor fan motor 4 Sensor unit 5 Room sensor support 6 Card support box 7 Noise filter 8 Fan capacitor transformer 9 Electronic card 1...

Страница 9: ...is commanded and controlled by an electronic microprocessor system 100 Right handle 101 Left handle 102 Filter 103 Fan breakaway starting capaci tor 104 Compressor 105 Compressor cap 106 Compr protec...

Страница 10: ...AX Cooling 21 C d b 16 C w b 32 C d b 23 C w b 10 C d b 43 C d b Heating 15 C d b 27 C d b 10 C w b 18 C w b Performance is referred to the following conditions Cooling indoor unit inlet air temperatu...

Страница 11: ...ply connector XS2 XP2 Motor M1 power supply connector XS3 Quick connector XT1 Power supply terminal board A I A I FLAPS ID1 ID2 12VAC SW IR HALL ST2 ST1 BLACK WHITE RED BLUE PINK YELLOW ORANGE RED 123...

Страница 12: ...alve INDOOR OUTDOOR UNIT WIRING DIAGRAMS OUTDOOR UNIT MULTIFILAR WIRING DIAGRAM A I A I XS1 XT2 YB1 M1 C1 C FR1 Z1 R S C2 M 4 2 1 3 5 6 XS1 XT2 M1 C1 C FR1 Z1 R S C2 M 4 2 1 3 5 6 YB1 M1 XT2 C1 C2 FR1...

Страница 13: ...indoor and the outdoor unit taking into consideration the minimum technical spaces maximum length of the refrige rant lines and the difference in level between the applian ces The indoor unit should b...

Страница 14: ...screws provided in the kit To facilitate dril ling operations it is advisable to fix the unit onto the fixing plate lift the front part and mark the drilling points on the wall through the relative h...

Страница 15: ...a floor or flat roof does not necessitate fixing the feet to the floor The feet should instead be placed on supports 70 80 mm to allow application of the conden sate drain line for units with heat pum...

Страница 16: ...t the conden sate is flowing out regularly The drainage pipe should have a 2 slope down towards the drain it should never slope upwards Check all the joints for leaks Apply thermal insulating material...

Страница 17: ...not spray insecticide or similar products on the unit CLEANING THE AIR FILTERS To ensure the long life and efficiency of your air conditioner follow these instructions 1 Clean the dust filter once a w...

Страница 18: ...to on Check Faulty electronic card PROBLEM CAUSE REMEDY Insufficient output Check see user booklet General failure Simultaneous blinking of indi cator lights Just wait 3 and the air conditioner will...