DeLonghi CF-CP 30 ARE 290 Скачать руководство пользователя страница 10

Power supply

V/f/Hz

Cooling capacity

Btu/h

W

Kcal/h

Consumption

W

Current requirement

A

E.E.R.
Dehumidifying

l/h

Heat output

Btu/h

W

Kcal/h

Consumption

W

Current requirement

A

C.O.P.
Quantity of R290 refrigerant

g

INDOOR UNIT
Air flow

m

3

/h

Sound level

dB(A)

Size:

length

mm

height

mm

depth

mm

Indoor unit weight

kg

OUTDOOR UNIT
Air flow

m

3

/h

Sound leve

dB(A)

Size:

length

mm

height

mm

depth

mm

Outdoor unit weight

kg

SPECIFICATIONS
Thermostat
Timer
Electronic defroster
LCD remote control
Microcomputer
Electronic diagnostics
Automatic night function
Fan speed

English

OPERATING LIMITS

TECHNICAL DATA

A

I

U

Operating cycle

Room air temperature

External air temperature

MIN

MAX

MIN

MAX

Cooling

21°C 

d.b.

.16°C 

w.b.

32°C 

d.b

./23°C 

w.b.

-10°C 

d.b.

43° C 

d.b.

Heating

15°C 

d.b.

27°C 

d.b.

-10°C 

w.b.

18°C 

w.b.

Performance is referred to the following conditions::

- Cooling

indoor unit inlet air temperature 27°C d.b., 19°C w.b.
external air temperature 35°C d.b., 24°C w.b.

- Heating

indoor unit inlet air temperature 20 d.b., 15°C w.b.
external air temperature 7°C d.b., 6°C w.b.

A

I







3 + silent

8013

12000

12000

17000

16320

2350

3520

3500

5000

4800

2025

3035

3020

4310

4137

740

1090

1050

1650

1570

3.9

5.7

5,7

7.6

7.6

3.18

3.23

3.20

3.03

3.0

1.3

1.5

1.5

2.2

1.9

8422

-

12000

-

19720

2470

-

3530

-

5800

2130

-

3030

-

5000

690

-

1055

-

1860

3.5

-

6

-

8.1

3.57

-

3.34

-

3.11

200 420 420 600 600

450

550

580

650

650

35

36

36

37

37

810

967

300

300

195

195

8

9

9

11

11

1350

1400

1600

2100

2500

4

45

46

46

47

660

800

500

640

230

280

35

35

35

51

52

CP 20

ARE 290

CF 30

ARE 290

CP 30

ARE 290

CF 40

ARE 290

CP 40

ARE 290

230/1/50

Содержание CF-CP 30 ARE 290

Страница 1: ...aordinary maintenance 35 User diagnostics 36 U I A U I A U I A 70 C A I U The following symbols have been used in some parts of this booklet and inside the appliance User Installer After sales service...

Страница 2: ...cubic metres The CP30 CF30 ARE 290 air conditioner must be used and stored in rooms with a volume of over 53 cubic metres The CF40 ARE 290 air conditioner must be used and stored in rooms with a volu...

Страница 3: ...r suitable absorbent material Prevent the liquid from entering into drains sewers cellars or work holes since the vapors could create a suffocating atmosphere First aid measures Inhalation Remove the...

Страница 4: ...ove the packing only when the air conditioner has been located in the point of installation Carefully remove the adhesive strips positioned on the air conditioner Packaging components must be disposed...

Страница 5: ...ONNECTION OFTHE UNIT I QUICK CONNECTOR I BASIC OPERATION The fast connector coupling uses a retractable sleeve and stem valve on the female half and a spring loaded poppet on the male side to create a...

Страница 6: ...he handle bottoms on the coupling body and the locking pin on models equipped with spring loaded locking pins pops into the handle hole properly see Figure 4 Connect the auxiliary electrical and conde...

Страница 7: ...couplings connected even when the system is not in use in order to minimize refrigerant effusion coupling damage and the entry of dirt or other foreign material If it is not possible to keep the coup...

Страница 8: ...a micropro cessor card 1 Wall mounting plate 2 Indoor unit base 3 Indoor fan motor 4 Sensor unit 5 Room sensor support 6 Card support box 7 Noise filter 8 Fan capacitor transformer 9 Electronic card 1...

Страница 9: ...is commanded and controlled by an electronic microprocessor system 100 Right handle 101 Left handle 102 Filter 103 Fan breakaway starting capaci tor 104 Compressor 105 Compressor cap 106 Compr protec...

Страница 10: ...AX Cooling 21 C d b 16 C w b 32 C d b 23 C w b 10 C d b 43 C d b Heating 15 C d b 27 C d b 10 C w b 18 C w b Performance is referred to the following conditions Cooling indoor unit inlet air temperatu...

Страница 11: ...ply connector XS2 XP2 Motor M1 power supply connector XS3 Quick connector XT1 Power supply terminal board A I A I FLAPS ID1 ID2 12VAC SW IR HALL ST2 ST1 BLACK WHITE RED BLUE PINK YELLOW ORANGE RED 123...

Страница 12: ...alve INDOOR OUTDOOR UNIT WIRING DIAGRAMS OUTDOOR UNIT MULTIFILAR WIRING DIAGRAM A I A I XS1 XT2 YB1 M1 C1 C FR1 Z1 R S C2 M 4 2 1 3 5 6 XS1 XT2 M1 C1 C FR1 Z1 R S C2 M 4 2 1 3 5 6 YB1 M1 XT2 C1 C2 FR1...

Страница 13: ...indoor and the outdoor unit taking into consideration the minimum technical spaces maximum length of the refrige rant lines and the difference in level between the applian ces The indoor unit should b...

Страница 14: ...screws provided in the kit To facilitate dril ling operations it is advisable to fix the unit onto the fixing plate lift the front part and mark the drilling points on the wall through the relative h...

Страница 15: ...a floor or flat roof does not necessitate fixing the feet to the floor The feet should instead be placed on supports 70 80 mm to allow application of the conden sate drain line for units with heat pum...

Страница 16: ...t the conden sate is flowing out regularly The drainage pipe should have a 2 slope down towards the drain it should never slope upwards Check all the joints for leaks Apply thermal insulating material...

Страница 17: ...not spray insecticide or similar products on the unit CLEANING THE AIR FILTERS To ensure the long life and efficiency of your air conditioner follow these instructions 1 Clean the dust filter once a w...

Страница 18: ...to on Check Faulty electronic card PROBLEM CAUSE REMEDY Insufficient output Check see user booklet General failure Simultaneous blinking of indi cator lights Just wait 3 and the air conditioner will...