CONNECTING THE FEEDER
CABLE
To connect the feeder cable to the cooker
it is necessary to:
■
Remove the 4 screws that hold
shield
A
behind the cooker.
■
Open completely the cable clamp
D
.
■
Position the U bolts onto terminal
block
B
(fig. 1.1) according to the
diagrams in figs. 1.2a - 1.2b.
■
Insert the feeder cable into the cable
save
C.
The supply cable must be
of a suitable size for the current
requirements of the appliance; see
the section “Feeder cable section”.
■
Connect the phase and earth cables
to terminal
B
according to figures
1.2a - 1.2b.
■
Pull the feeder cable and block it
with the cable clamp
D
■
Re-mount shield
A
.
N.B. The earth conductor must be left
about 3 cm longer than the others.
Figure 1.2b
FEEDER CABLE SECTION
type “H05RR-F”
230-240 V
3 x 4 mm2 (**)
230 -240 V3
4 x 2,5 mm
2
(**)
400 -415 V 3N
5 x 2,5 mm
2
(**)
400 -415 V 2N
4 x 2,5 mm
2
(**)
(**) – Connection with wall box connection
– Diversity factor applied
I N S T A L L A T I O N
230-240 V ~
2
3
4
5
1
N(L2)
PE
L1
230 V 3 - 240 V 3 ~
2
3
4
5
1
PE
L1
L2
L3
400 V 3N - 415 V 3N ~
2
3
4
5
1
PE
L1
L2 L3
N
400 V 2N - 415 V 2N ~
2
3
4
5
1
PE
L1
L2
N