14
Anchorage
clip
Anchorage
clip
I
I
V
V
I N S T A L L A T I O N
■
Remove the burner as shown in figure 1.24.
■
Using a 7 mm box spanner, unscrew the injector (indicated by the arrow
in fig. 1.25) and replace it by the proper one according to the kind of
gas.
■
Then replace the burner and other components repeating the above steps
in reverse order.
IMPORTANT:
Pay special attention to replace correctly the safety valve
probe "
V
" and the ignition electrode "
I
" as per figures 1.26 and 1.27.
Check the correct operation of the safety valve and the ignition electrode.
Figure 1.24
Figure 1.26
Figure 1.27
Figure 1.25
Содержание AP 1246 G
Страница 56: ...Rif 1688 5...