background image

 

 

TABLE  OF CONTENTS 

 

 

 

PAGE 

 

GENERAL  DESCRIPTION  & SPECIFICATIONS 

      

OPERATING  INSTRUCTIONS 

 

NAVIGATION 

 

 

BATTERY INSTALLATION 

 

4    

POWER  UP 

 

 

 

SETUP MENU 

 

METER USE 

 

MAIN  MENU 

 

 

 

 

METER FUNCTIONS 

 

PIN MODE 

 

MODE  – CONTINUOUS  /TRIGGERED 

 

 

    

CREATE/EDIT  A JOB 

 

10 

ALARM  SETTINGS 

 

11 

USE OF THE VARIOUS  SCALES 

 

12 

TESTING  PAPER, PAPER  CORES,  AND  CORRUGATED  PRODUCTS 

12 

USING  THE 0 –100  RELATIVE  SCALE 

12 

TESTING  BALED  SCRAP PAPER 

 

13 

APENDING  DATA TO A JOB 

 

14 

 

 

     

STORAGE 

 

14 

STORAGE  MENU 

 

15 

 

 

    

VIEW STATISTICS 

 

15 

STORED  READINGS 

 

16 

CLEAR  MEMORY 

 

17 

RESTORE  DEFAULTS 

 

17 

IR  LINK  TO PC 

 

18    

TROUBLE  SHOOTING  THE IR/LINK   

19

 

CARE  OF YOUR METER 

 

20 

SERVICE  FOR YOUR  METER 

 

20 

WARRANTY 

 

21 

 

 

 

 

 

This product is covered by EU directive 2002/96/EC  (WEEE). For disposal 
please contact your supplier  or local authorities for instructions as to best do so. 

 
 
 

 

Содержание RDM3-P

Страница 1: ...RDM3 P Paper Moisture Meter MANUAL Version 1 0 Rev 02 13 DELMHORST EUROPE TITANIUMLAAN 100 NL 5221 CK s HERTOGENBOSCH THE NETHERLANDS info Delmhorst eu www MoistureMetersDelmhorst com 31 0 73 6395080...

Страница 2: ...ING PAPER PAPER CORES AND CORRUGATED PRODUCTS 12 USING THE 0 100 RELATIVE SCALE 12 TESTING BALED SCRAP PAPER 13 APENDING DATA TO A JOB 14 STORAGE 14 STORAGE MENU 15 VIEW STATISTICS 15 STORED READINGS...

Страница 3: ...Three scales for o PAPER 5 3 23 o RELATIVE 0 100 scale and o BALED PAPER 8 40 NOTE Displayed readings outside of this nominal range should be taken as a no reading They are included in statistical ca...

Страница 4: ...nderside of the case at the bottom of the handle i Open the battery compartment by sliding the lid back while pressing on the release indent ii Ensure correct polarity and push the battery in flush wi...

Страница 5: ...efuse to stay on at power up This gradual warning system is intended to provide the user advanced battery status notice and give ample time for replacement before operational limitations occur NOTE St...

Страница 6: ...action changes the selected parameter s value for DONE and CANCEL parameters without assigned values the LEFT and RIGHT keys perform no function All parameter values are incremented using the RIGHT ke...

Страница 7: ...the battery is removed Meter Use This chapter describes each meter menu in detail as well as the use of each meter feature MAIN MENU The RDM 3P Main Menu is the default screen at power up It provides...

Страница 8: ...o a specific job More than one job can be defined with the same scale RDM 3P automatically configures MC READ Mode with the following default set of parameters when this feature is first accessed o De...

Страница 9: ...MODE option and pressing the SELECT key will change the measurement mode o Triggered mode causes a single reading to be taken every time the SELECT button is pressed Each reading is stored in memory T...

Страница 10: ...EAD Mode menu This is the same as selecting CANCEL Select JOB and use the LEFT or RIGHT keys to change the job number to the one desired When finished select DONE To abandon select CANCEL If the selec...

Страница 11: ...s Once ALARM is chosen pressing the SELECT key toggles the state of the alarm feature ON OFF The ON state is marked by the current alarm threshold value while the OFF state is indicated with an OFF st...

Страница 12: ...s not entirely embedded in the thickness of the sample the readings tend to indicate a lower than actual MC This can be overcome by testing more than one sample in stacks USING THE 0 100 RELATIVE SCAL...

Страница 13: ...or reject the material Since checking the moisture condition of bales is performed when buying and selling the specific value of the meter readings remains an element to be agreed upon between buyer a...

Страница 14: ...xisting jobs or create new ones at random There are no restrictions regarding measurement storage based on job number For example the user is free to take and store readings pertaining to job 3 then j...

Страница 15: ...cific job o The third line shows the Average MC value for all stored readings in the specific job o The fourth line shows the Standard Deviation for the specific job o The fifth line shows the Coeffic...

Страница 16: ...an only be reviewed in ascending sequence ex reading 1 2 3 etc The meter assists moving to a set of readings later in the sequence by allowing the user to specify a start point for this ascending sequ...

Страница 17: ...ately pressing the Left button causes the meter to subtract 10 from the current left side value o DONE Selecting this option signals to the meter that the user has completed the reading recall setup p...

Страница 18: ...to 30 cm 0 to 12 Operation 1 Begin by starting the Delmhorst Universal Application Program double click the application icon or chose the program from the Start Menu 2 Once the RDM3 and Base Unit are...

Страница 19: ...his is not the case check power connections o No connection to the PC The Base Unit must be connected to the PC through a serial cable Check connection b KBD This message occurs when the user presses...

Страница 20: ...our name address daytime phone and fax numbers or e mail address If you believe the meter is under warranty please provide the original sales slip or invoice Ship via UPS Express Mail Priority Mail or...

Страница 21: ...ctions in the Care of Your Meter section Under no circumstances shall DELMHORST be liable for any incidental indirect special or consequential damages of any type whatsoever including but not limited...