18 

 

o

 

Restore Defaults

:  This menu  option will erase the storage memory  AND  restore pre-

programmed  meter  defaults. This feature offers accidental feature access protection through 

the use of a subsequent memory  deletion  interactive confirmation  screen.

 

 

 

NOTE:

 

Memory deletion is irreversible

 

o

 

Exit

: This menu  options returns the meter to Main Menu. 

 

IR  LINK: 

o

 

This meter option initiates a wireless  communication  session during  which the currently stored 

readings  will  be downloaded to a PC. Before using  this feature, the target PC mus t be loaded 

with Delmhorst’s  Universal  Application Program  and a Delmhorst  Base Unit must be connected 

to an available  serial  port. Note that the Base Unit also requires  power for operation, supplied 

by an AC adapter – included in the PC/KIT. A serial  cable is also provided  in the PC/KIT.

 

 

Requirements: 

The wireless  communication  technology employed  in the meter  requires  line-of-sight access 

between the red side window of the meter and the receiving window of the Base Unit. Simply 

place the meter and Base  Unit on a flat surface, with the red side window of the meter  facing 

the receiving  window of the Base Unit. Separation requirements  between the meter and Base 

Unit are anywhere from  0 to 30 cm (0” to 12”). 

 

Operation: 

1.

 

Begin  by starting the Delmhorst  Universal  Application  Program  (double  click the application icon, or 

chose the program  from  the Start Menu). 

2.

 

Once the RDM

3

 and Base Unit are lined  up and the Base Unit is powered (a green LED  should be 

lit), select the IR Link  option in the Main Menu. The meter  will display  the message  “Linking…”  for a 

few seconds, followed by “Link  OK” when successful communication  was established  with the Base 

Unit. The Base Unit will also indicate communication  established by turning  off the green LED and 

turning  on a red LED.   

3.

 

Press the “Manage Data” button in the Delmhorst  Universal  Application Program.  The meter will 

display “Data” on the screen and the Base Unit will alternately turn on a yellow and red LED  while 

data transfer takes place (red indicates communication  between the meter and Base Unit, while 

yellow indicates communication  between the Base Unit and the PC). When finished,  the meter  will 

return to the Main Menu and the Base Unit will, once again, turn on its green LED. For further 

details on managing  the meter data in the PC please refer to the HELP  feature in the program. 

 

NOTE: 

The above sequence of events in initiating  communication  between the PC and the meter  is 

not mandatory.  The Application Program  may be started first, or the IR  Link  may be selected first. 

The Manage Data button may also be pressed before communication  is started between the Base 

Содержание RDM3-P

Страница 1: ...RDM3 P Paper Moisture Meter MANUAL Version 1 0 Rev 02 13 DELMHORST EUROPE TITANIUMLAAN 100 NL 5221 CK s HERTOGENBOSCH THE NETHERLANDS info Delmhorst eu www MoistureMetersDelmhorst com 31 0 73 6395080...

Страница 2: ...ING PAPER PAPER CORES AND CORRUGATED PRODUCTS 12 USING THE 0 100 RELATIVE SCALE 12 TESTING BALED SCRAP PAPER 13 APENDING DATA TO A JOB 14 STORAGE 14 STORAGE MENU 15 VIEW STATISTICS 15 STORED READINGS...

Страница 3: ...Three scales for o PAPER 5 3 23 o RELATIVE 0 100 scale and o BALED PAPER 8 40 NOTE Displayed readings outside of this nominal range should be taken as a no reading They are included in statistical ca...

Страница 4: ...nderside of the case at the bottom of the handle i Open the battery compartment by sliding the lid back while pressing on the release indent ii Ensure correct polarity and push the battery in flush wi...

Страница 5: ...efuse to stay on at power up This gradual warning system is intended to provide the user advanced battery status notice and give ample time for replacement before operational limitations occur NOTE St...

Страница 6: ...action changes the selected parameter s value for DONE and CANCEL parameters without assigned values the LEFT and RIGHT keys perform no function All parameter values are incremented using the RIGHT ke...

Страница 7: ...the battery is removed Meter Use This chapter describes each meter menu in detail as well as the use of each meter feature MAIN MENU The RDM 3P Main Menu is the default screen at power up It provides...

Страница 8: ...o a specific job More than one job can be defined with the same scale RDM 3P automatically configures MC READ Mode with the following default set of parameters when this feature is first accessed o De...

Страница 9: ...MODE option and pressing the SELECT key will change the measurement mode o Triggered mode causes a single reading to be taken every time the SELECT button is pressed Each reading is stored in memory T...

Страница 10: ...EAD Mode menu This is the same as selecting CANCEL Select JOB and use the LEFT or RIGHT keys to change the job number to the one desired When finished select DONE To abandon select CANCEL If the selec...

Страница 11: ...s Once ALARM is chosen pressing the SELECT key toggles the state of the alarm feature ON OFF The ON state is marked by the current alarm threshold value while the OFF state is indicated with an OFF st...

Страница 12: ...s not entirely embedded in the thickness of the sample the readings tend to indicate a lower than actual MC This can be overcome by testing more than one sample in stacks USING THE 0 100 RELATIVE SCAL...

Страница 13: ...or reject the material Since checking the moisture condition of bales is performed when buying and selling the specific value of the meter readings remains an element to be agreed upon between buyer a...

Страница 14: ...xisting jobs or create new ones at random There are no restrictions regarding measurement storage based on job number For example the user is free to take and store readings pertaining to job 3 then j...

Страница 15: ...cific job o The third line shows the Average MC value for all stored readings in the specific job o The fourth line shows the Standard Deviation for the specific job o The fifth line shows the Coeffic...

Страница 16: ...an only be reviewed in ascending sequence ex reading 1 2 3 etc The meter assists moving to a set of readings later in the sequence by allowing the user to specify a start point for this ascending sequ...

Страница 17: ...ately pressing the Left button causes the meter to subtract 10 from the current left side value o DONE Selecting this option signals to the meter that the user has completed the reading recall setup p...

Страница 18: ...to 30 cm 0 to 12 Operation 1 Begin by starting the Delmhorst Universal Application Program double click the application icon or chose the program from the Start Menu 2 Once the RDM3 and Base Unit are...

Страница 19: ...his is not the case check power connections o No connection to the PC The Base Unit must be connected to the PC through a serial cable Check connection b KBD This message occurs when the user presses...

Страница 20: ...our name address daytime phone and fax numbers or e mail address If you believe the meter is under warranty please provide the original sales slip or invoice Ship via UPS Express Mail Priority Mail or...

Страница 21: ...ctions in the Care of Your Meter section Under no circumstances shall DELMHORST be liable for any incidental indirect special or consequential damages of any type whatsoever including but not limited...

Отзывы: