TERA1x00 PC-over-IP Administrative Interface User Manual
TER0606004 Issue 3
© 2008 Teradici Corporation
Page 63 of 111
Figure 42: Connection Management Configuration
2.3.2.1 Enable Connection Management
If the
Enable Connection Management
option is enabled, the device can be
configured and controlled by an external connection manager.
2.3.2.2 Identify Connection Manager By
The
Identify Connection Manager
selector allows the administrator to choose
whether the connection manager is identified by IP address, or by Fully Qualified
Domain Name (FQDN). If connection management is disabled, this field is not
required and is not editable.
Table 10 shows the configuration parameters available when either method is
chosen. If an invalid IP address or DNS name is entered, the OSD will prompt the
administrator to correct it.
Table 10: Connection Manager Method
Method Data
Fields
IP address Connection Manager IP Address
FQDN
Connection Manager DNS name
2.3.2.3 Enable Event Log Notification
The
Enable Event Log Notification
field enables event notification from the PC-
over-IP Host and Portal devices to the connection management server.