Table 17. Equipment environment specification
Equipment environment specification
Product power off
1
Dry-bulb temperature
Relative humidity
Maximum wet-bulb temperature
5 to 45°C (40 to 113°F)
8% to 80% RH
26°C (79°F)
Product operation (equipment is powered on)
Dry-bulb temperature
Humidity range, non-
condensing
Maximum
dew point
temperature
4
Maximu
m wet-
bulb
tempera
ture
5
Maximu
m
elevatio
n
Allowab
le
2
Recom
mended
3
Maximu
m rate
of
change
Allowab
le
Recom
mended
Maximu
m rate
of
change
22°C (72°F) for
LTO 9
26°C
(79°F)
3050 m
(10,000
feet)
15 to
35°C
(59 to
95°F)
15 to
25°C
(59 to
77°F)
5°C/
hour
(9°F/
hour)
20% to
80% RH
20% to
50% RH
5% RH/
hour
with no
condens
ation
Note:
1. Product equipment is removed from the original shipping container and installed but not in use - for
example, during repair, maintenance, or upgrade.
2. Derate maximum dry-bulb temperature 1°C/300 m above 900 m (1.8°F/1,000 feet above 3,000
feet).
3. Derate maximum recommended dry-bulb temperature 1°C/300 m above 1,800 m (1.8°F/1,000 feet
above 6,000 feet).
4. Applies to LTO 9 drives
5. Applies to LTO drive generations 1 through 8.
Rack mount drive
Table 18. Rack mount drive specifications
Physical Specifications
Width
48.3 cm (19.0 in)
Length
44.0 cm (17.32 in)
Height
9.0 cm (3.54 in)
Weight
10.23 kg (22.55 lb) Chassis empty
Power Requirements
AC line voltage
100 - 240 VAC
Line frequency
50 - 60 Hz, auto-ranging
Line current at 100 VAC
1.9 A
Line current at 240 VAC
0.8 A
Chapter 5. Specifications 55