About Your System
29
E201E
POST Mem Test
BIOS POST memory test
failure.
See "Troubleshooting
System Memory" on
page 142. If problem
persists, see "Getting Help"
on page 167.
E201F
DRAC Config
Dell remote access
controller (DRAC)
configuration failure.
Check screen for specific
error messages.
Ensure that DRAC cables
and connectors are
properly seated. If problem
persists, see your DRAC
documentation.
E2020
CPU Config
CPU configuration failure. Check screen for specific
error messages.
E2021
Memory
Population
Incorrect memory
configuration. Memory
population order incorrect.
Check screen for specific
error messages. See
"Troubleshooting System
Memory" on page 142.
E2022
POST Fail
General failure after video. Check screen for specific
error messages.
E2110
MBE Crd #
DIMM ## & ##
One of the DIMMs in the
set implicated by "## &
##" has had a memory
multi-bit error (MBE). If
no memory card is present,
the "Crd #" string is left
out of the message.
See "Troubleshooting
System Memory" on
page 142.
Table 1-6.
LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
Book.book Page 29 Monday, September 14, 2009 12:57 PM
Содержание PowerVault DL2000
Страница 1: ...Dell PowerVault DL2000 Hardware Owner s Manual ...
Страница 10: ...10 Contents Glossary 169 Index 181 ...
Страница 62: ...62 Using the System Setup Program ...
Страница 128: ...128 Installing System Components ...
Страница 166: ...166 Jumpers and Connectors ...
Страница 168: ...168 Getting Help ...
Страница 180: ...180 Glossary ...
Страница 188: ...188 Index ...