About Your System
37
Manufacturing mode
detected
System is in
manufacturing mode.
Reboot to take the system
out of manufacturing mode.
MEMBIST failure -
The following
DIMM/rank has been
disabled by BIOS:
DIMM x Rank y
Faulty memory module(s). See "Troubleshooting
System Memory" on
page 142.
Memory address
line failure at
address
, read
value
expecting
value
Faulty or improperly
installed memory modules.
See "Troubleshooting
System Memory" on
page 142.
Memory double word
logic failure at
address
, read
value
expecting
value
Memory odd/even
logic failure at
address,
read
value
expecting
value
Memory write/read
failure at
address
, read
value
expecting
value
Memory tests
terminated by
keystroke.
POST memory test
terminated by pressing the
spacebar.
Information only.
Table 1-7.
System Messages
(continued)
Message
Causes
Corrective Actions
Book.book Page 37 Monday, September 14, 2009 12:57 PM