Dell PowerVault Storage Systems — Rack Installation Guide 1-7
Figure 1-5. Removing the 24U Rack Doors
CAUTION: Store the two doors where they cannot injure someone if the
doors accidently fall over.
If you want to reverse the door so that the handle is on the other side, perform the fol-
lowing steps:
1.
With the door open, lift out and fully retract all hinge pins.
2.
Remove the hinges and door brackets from the door frame.
3.
Replace the hinges and door brackets on the opposite side and switch the posi-
tion of the handle.
4.
Replace the rack door (see “Replacing the Rack Doors,” at the end of this
document).
Planning the Rack Installation
Use the Dell Rack Advisor software to determine where to install a DPE, DAE, or SPS
in the rack. You can also follow these general guidelines:
•
The DPE is 6.5 rack units (U) in height. (One U equals 1.75 inches.) The DAE is
3.5 U in height. The SPS is 1 U in height.
hinge insert
hinge
hinge pin