CL5262
Figure 105. Installing the bezel
Verify the operation of an added drive
Steps
1. From PowerStore Manager, select
Hardware
.
2. Select the appliance where you added the drive.
3. On the
Components
card, under
Drives
, expand
ExpansionEnclosure
and select the drive.
The status of the drive should read
Healthy
. If the status is still
Faulted
, wait a few minutes and refresh PowerStore
Manager. If the status does not change, ensure that the drive is correctly seated, or contact your service provider.
Replace a power supply module in an NVMe expansion
enclosure
Take the following actions to remove the faulted power supply module from the NVMe expansion enclosure and install a
replacement power supply.
Identify a faulted power supply from PowerStore Manager
Before you replace a power supply, use PowerStore Manager to identify its location within the system.
Steps
1. From PowerStore Manager, select
Hardware
.
2. Select the appliance that includes the power supply that you need to replace.
3. On the
Components
card, under
Rear View
, expand
ExpansionEnclosure
.
4. Expand the node that includes the power supply, and then select
PSU0
.
Faulted parts appear in red in the image of the system, and report a status of
Faulted
in the
State
field.
90
NVMe expansion enclosure service procedures