Error Code
Message Information
Details
An error was reported during a SD card read or write.
Action
Reseat the flash media. If the problem persists, see
Getting Help
.
RFM1014
Message
Removable Flash Media <
name
> is write protected.
LCD Message
Removable Flash Media <
name
> is write protected. Check SD Card.
Details
The card is write-protected by the physical latch on the SD card. A
write-protected card cannot be used.
Action
If unintended, remove the media and disable write protection.
RFM1201
Message
Internal Dual SD Module redundancy is lost.
LCD Message
Internal Dual SD Module redundancy is lost. Check SD Card.
Details
Either one or both the SD cards are not functioning properly.
Action
See
Getting Help
.
RFM2001
Message
Internal Dual SD Module <
name
> is absent.
LCD Message
Internal Dual SD Module <
name
> is absent. Check SD Card.
Details
The SD card module is not detected or not installed.
Action
If unintended, reinstall the SD module.
RFM2002
Message
Internal Dual SD Module <
name
> is offline.
Details
The SD card module is installed but may be improperly installed or
configured incorrectly.
Action
Reinstall the SD module.
RFM2004
Message
Failure detected on Internal Dual SD Module <
name
>.
LCD Message
Internal Dual SD Module <
name
> failed. Check SD Card.
Details
The SD card module is installed but improperly configured or failed to
initialize.
Action
Reinstall the SD module and remove and reinstall SD cards.
RFM2006
Message
Internal Dual SD Module <
name
> is write protected.
Details
The module is write-protected. Changes may not be written to the
media.
Action
If unintended, remove the media and disable write protection.