Installing System Components | 125
processor.
CAUTION: Using excess thermal grease can cause grease to contact the
processor shield, which can cause contamination of the processor socket.
8
Place the heat sink on the processor. See Figure 3-8.
9
Using a Phillips screwdriver, tighten the heat-sink retention screws. See
Figure 3-8.
10
Install the air duct(s). See "Installing the Air Duct" on page 117.
11
Install the system-board assembly. See "Installing a System-Board
Assembly" on page 116.
12
Reconnect the system to its electrical outlet and turn on the system,
including any attached peripherals.
13
Press <F2> to enter the System Setup program, and check that the
processor information matches the new system configuration. See
"System Setup Options at Boot" on page 46.
Expansion-Card Assembly and Expansion Card
Removing the Expansion Card
CAUTION: Many repairs may only be done by a certified service technician. You
should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow the safety instructions that came with
the product.
1
Recommend to turn off the system, including any attached peripherals,
and disconnect the system from its electrical outlet.
2
Remove the system-board assembly. See "Removing a System-Board
Assembly" on page 115.
3
Remove the three screws that secure the expansion-card assembly. See
Содержание PowerEdge C6145
Страница 1: ...Regulatory Model B05S DellPowerEdgeC6145 Systems Hardware Owner s Manual ...
Страница 78: ...78 Using the System Setup Program USB Drives Scroll to this item and press Enter to view the following screen ...
Страница 111: ...Installing System Components 111 Table 3 3 PSU Model and Quantity with CPLD 2 Node Configuration ...
Страница 112: ...112 Installing System Components Table 3 4 PSU Model and Quantity with Expander 1 Node Configuration ...
Страница 165: ...Installing System Components 165 Table 3 7 Memory Module Configurations and Limitation Memory Unit GB ...
Страница 241: ...Jumpers and Connectors 241 Sensor Board Connectors Figure 5 15 Sensor Board Connectors 1 power connector 2 sensor board ...