Installing System Components | 121
Processors
The following tables list the limited configurations of the C6145 system for
proper thermal conditions:
Table 3-5. Limited Configuration Matrix for Proper Thermal Condition on 2-Node System
Processor
(G34 TDP)
Hard Drive
QTY
Note
85 W
3.5" x12
2.5" x24
No PCI-E card on PCI-E slot 2
3.5” x8
2.5" x18
Support PCI-E cards on PCI-E slot 2 and slot 3
3.5" hard-drive blank and carrier should be put on the
four slots in the second row of the hard-drive slots as
Figure 1-1.
2.5" hard-drive blank and carrier should be put on the
hard-drive ID 10-12 and 22-24 as Figure 1-5.
115 W
3.5” x8
2.5" x18
Support PCI-E cards on PCI-E slot 2 and slot 3
3.5" hard-drive blank and carrier should be put on the
four slots in the second row of the hard-drive slots as
Figure 1-1.
2.5" hard-drive blank and carrier should be put on the
hard-drive ID 10-12 and 22-24 as Figure 1-5.
140 W
3.5" x8
No PCI-E card on PCI-E slot 2.
3.5" hard-drive blank and carrier should be put on the
four slots in the second row of the hard-drive slots as
Figure 1-1
and allow max ambient 30
o
C.
Содержание PowerEdge C6145
Страница 1: ...Regulatory Model B05S DellPowerEdgeC6145 Systems Hardware Owner s Manual ...
Страница 78: ...78 Using the System Setup Program USB Drives Scroll to this item and press Enter to view the following screen ...
Страница 111: ...Installing System Components 111 Table 3 3 PSU Model and Quantity with CPLD 2 Node Configuration ...
Страница 112: ...112 Installing System Components Table 3 4 PSU Model and Quantity with Expander 1 Node Configuration ...
Страница 165: ...Installing System Components 165 Table 3 7 Memory Module Configurations and Limitation Memory Unit GB ...
Страница 241: ...Jumpers and Connectors 241 Sensor Board Connectors Figure 5 15 Sensor Board Connectors 1 power connector 2 sensor board ...