About Your System
15
Table 1-3 lists the drive indicator patterns for RAID hard drives. Different patterns are displayed as drive
events occur in the system. For example, if a hard drive fails, the "drive failed" pattern appears. After the
drive is selected for removal, the "drive being prepared for removal" pattern appears, followed by the "drive
ready for insertion or removal" pattern. After the replacement drive is installed, the "drive being prepared for
operation" pattern appears, followed by the "drive online" pattern.
NOTE:
For non-RAID configurations, only the drive-activity indicator is active. The drive-status indicator is off.
Table 1-3.
Hard-Drive Indicator Patterns for RAID
Condition
Drive-Status Indicator Pattern
Identify drive/preparing for
removal
Blinks green two times per second
Drive ready for insertion or
removal
Off
Drive predicted failure
Blinks green, amber, and off.
Drive failed
Blinks amber four times per second.
Drive rebuilding
Blinks green slowly.
Drive online
Steady green.
Rebuild aborted
Blinks green three seconds, amber three seconds, and off six seconds.