Error Code Message Information
4. Reapply input power and turn on the system.
5. If the issue persists, see
Getting Help
.
CPU0703
Message
CPU bus initialization error detected.
LCD Message CPU bus initialization error detected. Power cycle system.
Details
System event log and operating system logs may indicate that the exception is external
to the processor.
Action
1. Check system and operating system logs for exceptions. If no exceptions are
found, continue.
2. Turn off the system and remove input power for one minute.
3. Ensure the processor is seated correctly.
4. Reapply input power and turn on the system.
5. If the issue persists, see
Getting Help
.
CPU0704
Message
CPU <
number
> machine check error detected.
LCD Message CPU <
number
> machine check error detected. Power cycle system.
Details
System event log and operating system logs may indicate that the exception is external
to the processor.
Action
1. Check system and operating system logs for exceptions. If no exceptions are
found, continue.
2. Turn off the system and remove input power for one minute.
3. Ensure the processor is seated correctly.
4. Reapply input power and turn on the system.
5. If the issue persists, see
Getting Help
.
FAN0000
Message
Fan <
number
> RPM is less than the lower warning threshold.
Details
Fan operating speed is out of range.
Action
Remove and reinstall the fan. If the issue persists, see
Getting Help
.
FAN0001
Message
Fan <
number
> RPM is less than the lower critical threshold.
LCD Message
Fan <
number
> RPM is outside of range. Check fan.
Details
Fan operating speed is out of range.
Action
Remove and reinstall the fan. If the issue persists, see
Getting Help
.
FAN1201
Message
Fan redundancy is lost.
LCD Message
Fan redundancy is lost. Check fans.
145
Содержание PE R720XD
Страница 1: ...Dell PowerEdge R720 and R720xd Owner s Manual Regulatory Model E14S Series Regulatory Type E14S001 ...
Страница 8: ...8 ...
Страница 118: ...118 ...
Страница 140: ...140 ...
Страница 156: ...156 ...