Using the BMC Management Utility
65
Subcommands
on
off
Turns the managed system’s front panel LED on or off. If the BMC supports
the IPMI extension
Chassis Identify On
command, then the
identify on
command turns the LED on indefinitely until the
identify off
command is
used to turn the LED off.
NOTE:
Acknowledgement or status check of the command is not displayed on the
command prompt. You should manually check the status on the system.
Options
-t
seconds
Specifies how long the LED is on. It should be no longer than 255 seconds.
Default Subcommand
If a subcommand is not specified, this command acts the same as the
identify
on
command.
Figure 3-6.
identify Option Example
sysinfo
Synopsis
sysinfo
[
fru
|
id
]