Configuring Your Managed System
33
Subnet Mask
The subnet mask for the static IP address.
NOTE:
IP address 169.254.0.2 subnet mask 255.255.0.0 is
returned when the BMC is unable to contact the DHCP
server.
Default Gateway
The IP gateway for the static IP address.
VLAN Enable
Enables or disables the virtual LAN ID.
VLAN ID
This field is read-only when
VLAN Enable
is set to
off
.
To enter a value, navigate to the VLAN ID field from
another field.
A valid value for the virtual LAN ID must be a number
from 1 to 4094.
NOTE:
If you enter a value outside the specified range,
either 1 or 4094 is entered, whichever is closest.
VLAN
This field is read-only when
VLAN Enable
is set to
off
.
Specifies the priority of the VLAN. The valid values
range from
Priority 0 - Priority 7
.
LAN Alert Enabled
Enables or disables LAN alerting.
Alert Policy Entry 1
Enables or disables the first alert destination.
Alert Destination 1
This field is read-only when
LAN Alert Enabled
is
set to
off
.
Enter the IP address of the first alert destination. Use
the Left or Right arrow keys to navigate to each octet.
Use the numeric keypad to enter each octet.
The following IPv4 rules apply:
• IP addresses cannot be
127.xxx.xxx.xxx
, where
xxx
is
between
0-255
.
• The first octet must be between
1-223
(i.e.
143.xxx.xxx.xxx
)
• The last octet must not be
0
or
255
(i.e.
xxx.xxx.xxx.0
or
xxx.xxx.xxx.255
)
Table 2-1.
Remote Access Configuration Utility
(continued)
Option
Description
Содержание External OEMR 1435
Страница 8: ...8 Contents ...
Страница 13: ...Introduction 13 Figure 1 1 BMC Configuration Matrix ...
Страница 24: ...24 Introduction ...
Страница 102: ...102 Using the BMC Management Utility ...
Страница 124: ...124 Escape Key Sequences ...
Страница 152: ...152 Glossary ...
Страница 156: ...156 Index ...