Dell EqualLogic Configuration Guide v11.3
25
4
SAN Design
An EqualLogic iSCSI SAN can be operated in any network that supports the industry standards and IP
subnet design guidelines described in this section. Because of this flexibility, there are many network
design and configuration choices that can affect SAN performance. The following sections provide
details related to network design and configuration to support the use of an EqualLogic SAN.
4.1
Implementation of Standards
EqualLogic SANs are based on industry standards. The following standards are required to support all
host to target communications and member to member communications:
IETF Standards
o
IETF RFC1122 ―Requirements for Internet Hosts – Communications Layers‖
o
IETF RFC1123 ―Requirements for Internet Hosts – Application and Support‖
o
IETF RFC3270 ―Internet Small Computer Systems Interface (iSCSI)‖
IEEE Standards
o
802.1
o
802.3
iSNS Support
An Internet Storage Name Service
3
(iSNS) server can support discovery, management and configuration
of group members by dynamically updating information about the iSCSI target names for group
volumes. Once the IP address of an iSNS server is entered in an iSCSI initiator’s configuration utility,
the setting is persistent across initiator sessions. A PS Series group can be configured to register with
up to three iSNS servers.
4.2
General Requirements and Recommendations
For EqualLogic PS Arrays, the following general SAN design
requirements
apply:
For all members (arrays) in a given SAN Group all ports should be connected to the same
subnet. This allows the arrays to communicate with each other as a group of peer members.
The arrays must be in the same subnet as the group’s ―well known‖ IP address.
Rapid Spanning Tree Protocol must be enabled if the SAN infrastructure has more than two
switches in a non-stacked configuration.
3
The Internet Storage Name Service (iSNS) specification:
http://tools.ietf.org/html/rfc4171
Note:
Starting with Firmware V4.1.4, volume and snapshot identifiers are no longer
automatically published to iSNS servers. This applies to new volumes and snapshots as well
as volumes and snapshots that existed before the group was upgraded to V4.1.4.
Note:
Hosts can be in a different subnet as long as those hosts have layer 3 routing available
to the subnet containing the arrays and the group’s well known IP address.
Содержание EqualLogic PS4000
Страница 1: ...Dell EqualLogic Configuration Guide Dell EqualLogic Storage Infrastructure and Solutions ...
Страница 11: ...Dell EqualLogic Configuration Guide v11 3 6 Figure 1 Partially Connected Controller Failover ...
Страница 26: ...Dell EqualLogic Configuration Guide v11 3 21 Figure 5 Replication Partnerships with Multiple Groups ...
Страница 44: ...Dell EqualLogic Configuration Guide v11 3 39 Figure 14 Mixed Speed Redundant SAN ...
Страница 51: ...Dell EqualLogic Configuration Guide v11 3 46 Figure 19 Stack to Stack Uplink Using 1 GbE Links ...