Figure 115. Sliding the node halfway into the chassis
3. Pull the black release tab out completely, and slide the rest of the node back into the chassis.
The black release tab slides back into the system as it is inserted.
Figure 116. Installing the node
4. Pull the orange release trigger and push in gently to re-engage the locking mechanism.
If the black release tab comes out when pulled, the locking mechanism is not engaged.
Power up the node
Power up the node as described in
.
Verify the operation of a replacement part
Steps
1. From PowerStore Manager, select Hardware.
2. Select the appliance where you replaced the faulted part.
3. From the
Hardware
card, select the view of the system where the part was replaced.
The status of the replacement part should read
Healthy
. If the status is still
Faulted
, wait a few minutes and refresh PowerStore
Manager. If the status does not change, ensure that the part is correctly seated, or contact your service provider.
Base enclosure service procedures
81