Error Code
Message Information
Action
Remove and reinstall the power supply at the next service window. If
the issue persists, see
Getting Help
.
PSU0003
Message
The power input for power supply <
number
> is lost.
Details
The power supply is installed correctly but an input source is not
connected or is not functional.
Action
Verify the input source is attached to the power supply. Verify the
input power is within the operating requirements for the power
supply.
PSU0006
Message
Power supply <
number
> type mismatch.
Details
Power supplies should be of the same input type and power rating.
Action
Install matched power supplies and review proper configuration in
this manual.
PSU0016
Message
Power supply <
number
> is absent.
Details
The power supply has been removed or has failed.
Action
1. Remove and reinstall the power supply.
2. Check cables and subsystem components in the system for
damage.
3. If the issue persists, see
Getting Help
.
PSU0031
Message
Cannot communicate with power supply <
number
>.
Details
The power supply may operate, however power supply monitoring is
degraded. System performance may be degraded.
Action
Remove and reinstall the power supply. If the issue persists, see
Getting Help
.
PSU0032
Message
The temperature for power supply <
number
> is in a warning range.
Details
System performance may be degraded.
Action
Check the system operating environment, including airflow and inlet
temperature. Check system logs for temperature and thermal
component failures.
PSU0033
Message
The temperature for power supply <
number
> is outside of the
allowable range.
117