Error Code
Message Information
Action
Cycle input power, update component drivers, if device is removable,
reinstall the device.
PCI1360
Message
A bus fatal error was detected on a component at slot <
number
>.
Details
System performance may be degraded, or system may fail to operate.
Action
Cycle input power, update component drivers, if device is removable,
reinstall the device.
PDR0001
Message
Fault detected on drive <
number
>.
Details
The controller detected a failure on the disk and has taken the disk
offline.
Action
Remove and re-seat the failed disk. If the issue persists, see
Getting
Help
.
PDR1016
Message
Drive <
number
> is removed from disk drive bay <
bay
>.
Details
The controller detected that the drive was removed.
Action
Verify drive installation. Re-seat the failed drive. If the issue persists,
see
Getting Help
.
PST0128
Message
No memory is detected.
Details
System BIOS was unable to detect memory in the system.
Action
Re-seat the memory modules. If the issue persists, see
Getting Help
.
PST0129
Message
Memory is detected, but is not configurable.
Details
System BIOS detected memory, but was unable to configure the
memory for system operation.
Action
Compare system memory installation to supported system memory
configurations.
PSU0001
Message
Power supply <
number
> failed.
Action
Remove and reinstall the power supply. If the issue persists, see
Getting Help
.
PSU0002
Message
A predictive failure detected on power supply <
number
>.
Details
System performance and power redundancy may be degraded or
lost.