Enter the
ipmi user list
command to verify the IPMI users.
#
ipmi user list
Name User Id Privilege
------ ------- -------------
ipmi2 3 ADMINISTRATOR
ipmi1 2 ADMINISTRATOR
------ ------- -------------
Total users: 2
9. Enter the
ipmi user change
command to change the password of an IPMI user if needed:
#
ipmi user change ipmi1 password
10. Because the system disks and Fibre Channel I/O modules are moved from the old chassis to the new chassis, no changes are
required for drive mappings or access groups. If such changes are required, however, use the details captured in
on page 53 to confirm FC I/O configuration. Refer also to the
Data Domain System Controller
Upgrade Guide
for more information.
Bring HA back online
About this task
For HA systems, bring the HA configuration back online.
Steps
1. Run the
ha online
command on the standby node to bring the HA configuration back online.
2. For HA systems that were failed over to the standby node before the component replacement, optionally fail the system
back to the original active node. Run the
ha status
command to verify that the HA pair can failover and the
ha
failover
on the current active node to restore the original active node.
Field Replaceable Units
59