Table 46 Primary node cabling instructions (continued)
String
(Loop)
I/O - Port
Shelf Port
Length
2
I/O 7 - Port 1
A controller port 0 of shelf V2.1
2M
2
I/O 2 - Port 1
B controller port 0 of the highest number shelf in V2
2M
3
I/O 7 - Port 2
A controller port 0 of shelf V3.1
2M
3
I/O 2 - Port 2
B controller port 0 of the highest number shelf in V3
5M
4
I/O 7 - Port 3
A controller HOST
port of the SSD shelf
2M
4
I/O 2 - Port 3
B controller HOST
port of the SSD shelf
2M
a. Cable lengths shown are designed for Data Domain racks. Longer cables (up to 5M) can be
used.
Table 47 Standby node cabling instructions
String
(Loop)
I/O - Port
Shelf Port
Length
1
I/O 7 - Port 0
B controller port 2 of shelf V1.1
2M
1
I/O 2 - Port 0
A controller port 2 of the highest number shelf in V1
2M
2
I/O 7 - Port 1
B controller port 2 of shelf V2.1
2M
2
I/O 2 - Port 1
A controller port 2 of the highest number shelf in V2
2M
3
I/O 7 - Port 2
B controller port 2 of shelf V3.1
2M
3
I/O 2 - Port 2
A controller port 2 of the highest number shelf in V3
5M
4
I/O 7 - Port 3
A controller EXPANSION
port of the SSD shelf
2M
4
I/O 2 - Port 3
B controller EXPANSION
port of the SSD shelf
2M
a. Cable lengths shown are designed for Data Domain racks. Longer cables (up to 5M) can be
used.
Connect Cables and Power on
66
Data Domain DD6300, DD6800, and DD9300 Systems
6.1
Hardware Overview and Installation Guide
Содержание DD6300
Страница 6: ...FIGURES 6 Data Domain DD6300 DD6800 and DD9300 Systems 6 1 Hardware Overview and Installation Guide ...
Страница 8: ...TABLES 8 Data Domain DD6300 DD6800 and DD9300 Systems 6 1 Hardware Overview and Installation Guide ...
Страница 10: ...Revision history 10 Data Domain DD6300 DD6800 and DD9300 Systems 6 1 Hardware Overview and Installation Guide ...