About Your System
31
E1714
Unknown
error. Review
& clear SEL.
The system BIOS
determined there has been
an error in the system, but is
unable to determine its
origin.
Check the SEL for more
information and then
clear the SEL. Remove
AC power to the system
for 10 seconds and restart
the system.
If the problem persists,
see "Getting Help" on
page 195.
E1715
Fatal I/O
Error. Review
& clear SEL.
The system BIOS
determined there has been a
fatal error in the system.
Check the SEL for more
information, and then
clear the SEL. Remove
AC power to the system
for 10 seconds, and restart
the system.
If the problem persists,
see "Getting Help" on
page 195.
E1716
Chipset IERR
Bus
##
Dev
##
Function
##
.
Review &
clear SEL.
The system BIOS reported a
chipset internal error that
resides in bus ##, device
##, function ##.
Check the SEL for more
information, and then
clear the SEL. Remove
AC power to the system
for 10 seconds, and restart
the system.
If the problem persists,
see "Getting Help" on
page 195.
E1717
CPU
#
internal
error. Review
& clear SEL.
The system BIOS
determined that the
specified processor has had
an internal error.
Check the SEL for more
information, and then
clear the SEL. Remove
AC power to the system
for 10 seconds, and restart
the system.
If the problem persists,
see "Getting Help" on
page 195.
Code
Text
Causes
Corrective Actions
book.book Page 31 Thursday, February 18, 2010 2:06 PM
Содержание 810
Страница 1: ...Dell PowerEdge R810 Hardware Owner s Manual Regulatory Model E05S Regulatory Type E05S001 ...
Страница 80: ...80 Using the System Setup Program and UEFI Boot Manager ...
Страница 135: ...Installing System Components 135 Figure 3 23 Installing and Removing the Heat Sink 1 heat sink 2 release levers 2 1 2 ...
Страница 160: ...160 Installing System Components ...
Страница 194: ...194 Jumpers and Connectors ...
Страница 196: ...196 Getting Help ...
Страница 202: ...Index 202 ...