19
Dell EMC VxRail Multirack Deployment Guide
Note:
Figure 2 provides a list of the supported switches and operating systems for VxRail deployments.
4.2.2
Verify license installation
Run the command
show license status
command to verify license installation. Locate the
License
Type:
field and verify that
PERPETUAL
displays in the field.
OS10#
show license status
System Information
---------------------------------------------------------
Vendor Name : Dell EMC
Product Name : S5248F-ON
Hardware Version: A00
Platform Name : x86_64-dellemc_s5248f_c3538-r0
PPID : CN046MRJCES0085N0006
Service Tag : AAAAAAA
License Details
----------------
Software : OS10-Enterprise
Version : 10.4.2.0
License Type : PERPETUAL
License Duration: Unlimited
License Status : Active
License location: /mnt/license/GPZQG02.lic
---------------------------------------------------------
Note:
If an evaluation license is installed, licenses purchased from Dell EMC are available for download on
Dell Digital Locker
. See the
OS10 Enterprise Edition User Guide
for installation instructions.
4.2.3
Factory default configuration
The configuration commands begin with the Dell EMC Networking switches at their factory default settings.
Dell EMC Networking switches running the Dell EMC OS10 Enterprise Edition (OS10EE) can be reset to their
default configuration using the following commands:
OS10#
delete startup-configuration
Proceed to delete startup-configuration [confirm yes/no(default)]:
y
OS10#
reload
System configuration has been modified. Save? [yes/no]:
n
Proceed to reboot the system? [confirm yes/no]:
y
When complete, the switch reboots to the factory default configuration.
Note:
By default, OS10EE has Telnet disabled, SSH enabled, and the OOB management interface that is
configured to get an IP address using DHCP. The default username and password are both
admin
. Dell EMC
recommends changing the admin password to a complex password when logging in for the first time.