![Dell EMC PowerEdge T340 Скачать руководство пользователя страница 123](http://html1.mh-extra.com/html/dell-emc/poweredge-t340/poweredge-t340_installation-and-service-manual_2468319123.webp)
Temperature
Specifications
Fresh air
For information about fresh air, see the
Expanded operating temperature
section.
Maximum temperature gradient (operating and
storage)
20°C/h (36°F/h)
Table 23. Relative humidity specifications
Relative humidity
Specifications
Storage
5% to 95% RH with 33°C (91°F) maximum dew point.
Atmosphere must be noncondensing at all times.
Operating
10% to 80% RH with 29°C (84.2°F) maximum dew point.
Table 24. Maximum vibration specifications
Maximum vibration
Specifications
Operating
0.26 G
rms
at 5 Hz to 350 Hz (all operation orientations)
Storage
1.88 G
rms
at 10 Hz to 500 Hz for 15 minutes (all six sides tested)
Table 25. Maximum shock pulse specifications
Maximum shock pulse
Specifications
Operating
Six consecutively executed shock pulses in the positive and negative x, y, and z
axis of 6 G for up to 11 ms.
Storage
Six consecutively executed shock pulses in the positive and negative x, y, and z
axis (one pulse on each side of the system) of 71 G for up to 2 ms.
Table 26. Maximum altitude specifications
Maximum altitude
Specifications
Operating
3048 m (10,000 ft)
Storage
12,000 m (39,370 ft)
Table 27. Operating temperature derating specifications
Operating temperature derating
Specifications
Up to 35°C (95°F)
Maximum temperature is reduced by 1°C/300 m (1°F/547 ft), above 950 m (3,117
ft).
35–40°C (95–104°F)
Maximum temperature is reduced by 1°C/175 m (1°F/319 ft), above 950 m (3,117
ft).
40–45°C (104–113°F)
Maximum temperature is reduced by 1°C/125 m (1°F/228 ft), above 950 m (3,117
ft).
Technical specifications