System diagnostics and indicator codes
The diagnostic indicators on the system front panel display system status during system startup.
Topics:
•
•
System health and system ID indicator codes
•
iDRAC Quick Sync 2 indicator codes
•
iDRAC Direct LED indicator codes
•
•
Power supply unit indicator codes
•
•
Status LED indicators
NOTE:
The indicators display solid amber if any error occurs.
Table 23. Status LED indicators and descriptions
Icon
Description
Condition
Corrective action
Drive
indicator
The indicator turns solid amber if
there is a drive error.
•
Check the System Event Log to determine if the drive has an error.
•
Run the appropriate Online Diagnostics test. Restart the system and
run embedded diagnostics (ePSA).
•
If the drives are configured in a RAID array, restart the system, and
enter the host adapter configuration utility program.
Temperature
indicator
The indicator turns solid amber if
the system experiences a thermal
error (for example, the ambient
temperature is out of range or
there is a fan failure).
Ensure that none of the following conditions exist:
•
A cooling fan has been removed or has failed.
•
System cover, air shroud, memory module blank, or back filler bracket is
removed.
•
Ambient temperature is too high.
•
External airflow is obstructed.
If the problem persists, see
Electrical
indicator
The indicator turns solid amber if
the system experiences an
electrical error (for example,
voltage out of range, or a failed
power supply unit (PSU) or voltage
regulator).
Check the System Event Log or system messages for the specific issue. If
it is due to a problem with the PSU, check the LED on the PSU. Reseat the
PSU.
If the problem persists, see
Memory
indicator
The indicator turns solid amber if a
memory error occurs.
Check the System Event Log or system messages for the location of the
failed memory. Reseat the memory module.
3
System diagnostics and indicator codes
33
Содержание PowerEdge R840
Страница 1: ...Dell EMC PowerEdge R840 Technical Specifications Regulatory Model E49S Series Regulatory Type E49S001 ...
Страница 15: ...Figure 14 Electrical overview Figure 15 CPU installation Dell EMC PowerEdge R840 system overview 15 ...
Страница 16: ...Figure 16 Express service tag 16 Dell EMC PowerEdge R840 system overview ...