Chapter 4: Configuring Networking
22
Dell EMC Ready Stack: Microsoft Hyper-V on PowerEdge 14G Servers and Unity Storage
Deployment Guide
Configuring the Dell EMC Networking S3048-ON switch
The Dell EMC Networking S3048-ON switch serves as the OOB management switch for
the Ready Stack. A single switch is used because this connectivity is not considered
critical for workload operations. To begin configuring the switch, use a laptop with a serial
connection and terminal emulator software such as PuTTY.
Perform the following steps to configure the Dell EMC Networking S3048-ON switch.
Note:
After Step 2, the commands are the same as for configuration of the S5248F-ON switch.
See
Configuring Dell EMC Networking S5248F-ON switches
on page 17.
1.
Using an RJ45 to serial cable included with your switch, connect one end to your
workstation and the other end to the RS-232 console port of the switch, as shown
in the following figure.
Figure 4.
Serial port
2.
Using terminal emulation software, configure the appropriate COM port as follows:
115200 baud rate
No parity/no flow control
8 data bits/1 stop bit
3.
After a successful connection, enter configuration mode by running the following
commands:
OS10# configure terminal
4.
Configure the hostname and time zone, and set a username/password for EXEC
mode by running the following commands:
OS10(config)# hostname SWOOB
SWOOB(config)# username
<username>
password
<password>
role
sysadmin
SWOOB(config)# clock timezone
<time zone, example CST -6 0>
5.
Configure routing to your default gateway and save the configuration by running
the following commands:
SWOOB(config)# ip route 0.0.0.0/0 172.90.100.254
SWOOB(config)# do write
Configure the
S3048-ON switch