Figure 4 Removing the DC power cord
Spring
Release
CL5060
3. Turn the captive screw counterclockwise to release the power cooling module, and remove
the module.
NOTICE
To protect a running system from overheating, the enclosure will power down
unless you replace the power cooling module within two minutes.
Figure 5 Removing a power cooling module
CL5662
2
1
Installing power cooling module
This procedure describes how to install a power cooling module in the DAE.
Before you begin
Procedure
1. Install the power cooling module in the enclosure:
a. Gently insert the new power cooling module into the enclosure, being sure the module is
completely seated.
b. Secure the module with the captive screw.
Removing and replacing FRUs
20
Dell EMC ES40 Expansion Shelf Guide Field Replacement Unit Guide