Once the heat sink locks onto the carrier, remove the heat sink and processor assembly from the processor tray.
Figure 16. Removing the processor assembly from the processor tray
5
Align the processor assembly on the server board, until it is seated firmly in place.
6
In the marked order, tighten the retaining screws to secure the processor assembly.
Figure 17. Installing the processor assembly
Table 42. Assembly material
Description
Description Quantity
Torque (lbs/inch)
CPU HSK screw
2
12 ± 0.2
7
Install the air shroud between the heat sinks. Make sure the air shroud is locked in place.