Trouble shooting
Section 6
34
Part Number: 9291000 06/22
Parem.
Label Description
Min
Max
Default
U.M.
Type
PA
Password
-99
99
-19
Number
User
Language
/LI
Language
(Italian, English, German, French, Spanish, Polish, Russian)
0
6
0
°C
User
Probes
/1
Cabinet probe calibration
-10
10
0
°C
User
/2
Evaporator probe calibration
-10
10
0
°C
User
/3
Needle probe calibration
-10
10
0
°C
User
/4
Condenser probe calibration
-10
10
0
°C
User
/5
Evaporator probe activation (0=No, 1=Yes)
0
1
1
Flag
/6
Cabinet/evap/condenser probe type (Ntc=0, Ptc=1)
0
1
0
Flag
/7
Products 1 & 2 probe type (Ntc=0, Ptc=1, Pt1000=2)
0
2
2
Flag
/8
T° Scale (0=Fahrenheit, 1=Celsius)
0
1
1
Flag
User
/9
Product 1 probe activation (0=No, 1=Yes)
0
1
1
Flag
/10
Pressure input activation (0=No, 1=Yes)
0
1
1
Flag
/11
Condenser probe activation (0=No, 1=Yes)
0
1
0
Flag
/12
Product 2 probe second activation (0=No, 1=Yes)
0
1
0
Flag
Chilling-Quick Freezing
C0
Cabinet probe differential
1
15
3
°C
User
Accessing Parameters
Accessing User Parameters
In order to access the User parameters, you must first put
the machine into Stand-by mode. Next, press and hold the
DRY or
icon for 3-5 seconds. The display will show the
PA parameter and the value. In order to scroll through the
parameters, use the up and down arrow keys. Pressing the
Cycle Mode button or the
icon, the value will flash. While
flashing the value can be adjusted with the up or down
arrow buttons. Save or select the value by pressing the Cycle
button again.
Accessing Service Parameters
In order to access the Service parameters, you must first put
the machine into Stand-by mode. Next, press and hold the
DRY or
icon for 3-5 seconds. The display will show the
PA parameter and the value. In order to access the service
parameters, scroll to “-19” in the PA, by using the up and
down arrow keys. Pressing the Cycle Mode button or the
icon to enter.
Reset Factory Parameters
In order to reset the factory settings, you must first put the
machine into Stand-by mode. Next, press and hold the DRY
or
icon for 3-5 seconds. The display will show the PA
parameter and the value. Scroll to “+25” in the PA, by using
the up and down arrow keys. Pressing the Cycle Mode
button or the
icon to initiate. Once the reset is
completed, the unit will resume in Stand-by mode.
Содержание CV10E
Страница 3: ...THIS PAGE INTENTIONALLY LEFT BLANK Part Number 9291000 06 22 3 ...
Страница 11: ...THIS PAGE INTENTIONALLY LEFT BLANK Section 2 Specifications Part Number 929100 06 22 11 ...
Страница 17: ...Section 3 Installation Part Number 9291000 06 22 17 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 25: ...Section 4 Operation Part Number 9291000 06 22 25 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 39: ...Section 6 Trouble shooting Part Number 9291000 06 22 39 ...