Section 3
Installation
Part Number: 9291000 06/22 13
Leveling
After the unit has been placed in the desired location, units
with legs must be leveled. Level units from front to back
and from side to side. Leveling will insure proper door
operation and removal of condensate. Units with casters
must have the caster brake set so the unit cannot move.
Stabilizing
It is very important that all legs are properly adjusted to
keep the unit level, evenly distribute the weight and to
make sure the unit will not rock, lean or be unstable.
Leg & Caster Installation
n
Warning
The unit must be installed in a stable condition with
the front wheels locked. Locking the front casters after
installation is the owner’s and operator’s responsibility.
n
Warning
Use a jack to lift the refrigeration unit off the ground
just far enough to remove the leg/caster. Place blocking
underneath the unit. Do not work underneath a raised
unit without proper blocking. Do not lift the unit more
than necessary to remove the leg/caster. Lifting the unit
too far can make the unit unstable.
Air Flow
Blast Chiller Units
Units on castors or legs need a minimum of 2 inches
underneath the generator for proper airflow.
Clearance Minimums
Sides
0”
Back
5”
Bottom
2”
Installation
,
,
All stages of installation must be carried out in
compliance with the national standards in force
according to the manufacturer’s instructions and
by professionally qualified personnel.
Installation of the appliance and of the refrigerating
unit must only be carried out by technicians of the
manufacturer or by skilled personnel.
If the machine was supplied with a remote condensing
unit, it is the installer’s responsibility to check all the
connections in accordance with the instructions provided
for the installation of the systems and machinery.
The installer is advised to use the appropriate personal
protective equipment necessary for processing and in
compliance with the regulations in force.
Transportation and handling
The net and gross weight of this appliance can be found
on the external packaging.
Loading and unloading of the appliance and/or of the sub-
systems from the means of transport can be performed
using a forklift truck or fork pallet truck, the length of
which is more than half that of the unit or using cranes
where the appliance/sub-system is fitted with eyebolts.
The lifting equipment must be chosen according to the
size of the packaged machine/components and with
sufficient capacity. For handling of the appliance/sub-
systems, every precaution must be taken not to damage
them, respecting the indications on the packaging.
Unpacking and disposal
Remove all cardboard or the wooden crate from the base
on which the machine is placed. Then lift the machine/
sub-assemblies with a suitable means (forklift truck);
remove the wooden base and position the machine/sub-
assemblies in the place provided.
After removing the packaging, verify the integrity of the
machine/sub-assemblies in case of uncertainty do not use
it and contact the distributor.
Remove the protective PVC film on the stainless steel
panels from all sides both internally and externally.
Содержание CV10E
Страница 3: ...THIS PAGE INTENTIONALLY LEFT BLANK Part Number 9291000 06 22 3 ...
Страница 11: ...THIS PAGE INTENTIONALLY LEFT BLANK Section 2 Specifications Part Number 929100 06 22 11 ...
Страница 17: ...Section 3 Installation Part Number 9291000 06 22 17 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 25: ...Section 4 Operation Part Number 9291000 06 22 25 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 39: ...Section 6 Trouble shooting Part Number 9291000 06 22 39 ...