V0913, 5.14
•
Yes = allowed
Backstop-die, intermediate bend
Set to allow if there may be a bend between the die and backstop.
Selection possibilities:
•
Permitted
•
If unavoidable permitted: if it results that no solutions are to be found, than it is
permitted
•
Prohibited: never allowed.
Edge tolerance
In case backstop is against flat sheet an angle tolerance is allowed (deviation from
horizontal). To be programmed in degrees of tolerance (0 - 90° input).
90 Degree tolerance
The maximum allowed deviation from vertical (90°), when the backgauge is against a
bent angle which is not 90°.