Troubleshooting
DeLaval voluntary milking system VMS
94897201.pdf
2007-12-18
M
m
Alarm text
Type
Meaning
Action
M
m
Alarm text
Type
Meaning
Action
5
126
Did not get
water from
RA-unit
within...
minutes
Stop alarm
Water that should be delivered
from "ReceiveAll" equipment did
not became available within time.
ReceiveAll is optional, only used at
some installations. Cleaning will be
aborted automaticly.
Try to find out why water was not available.
Call serviceman if problem remains.
5
126
Did not get
water from
RA-unit
within...
minutes
Stop alarm
Water that should be delivered
from "ReceiveAll" equipment did
not became available within time.
ReceiveAll is optional, only used at
some installations. Cleaning will be
aborted automaticly.
Try to find out why water was not available.
Call serviceman if problem remains.
5
127
Both low and
high sensor
in receiver
active
Stop alarm
Level sensor in receiver indicated
both high and low level at the
same time.
Call service technician if several alarms.
Sensor should be checked.
5
127
Both low and
high sensor
in receiver
active
Stop alarm
Level sensor in receiver indicated
both high and low level at the
same time.
Call service technician if several alarms.
Sensor should be checked.
5
128
Timeout
changing
milk filter
Stop alarm
If change of milk filter was started
but not completed within time this
alarm will be given.
Make sure the filter change operation is
completed.
5
128
Timeout
changing
milk filter
Stop alarm
If change of milk filter was started
but not completed within time this
alarm will be given.
Make sure the filter change operation is
completed.
5
129
Milk diverted
due to MDi,
dest %...f
Notfication
See alarm text.
Check the cows that caused the notification.
Depending on the strategy at the farm the
thresholds can be changed. Lowering the
thresholds will increase the
diversion/notifications while increasing the
threshold will decrease the number of
diversions/notifications. The thresholds are
changed in Animal>VMS Cow>Automatic
diversion.
5
129
Milk diverted
due to MDi,
dest %...f
Notfication
See alarm text.
Check the cows that caused the notification.
Depending on the strategy at the farm the
thresholds can be changed. Lowering the
thresholds will increase the
diversion/notifications while increasing the
threshold will decrease the number of
diversions/notifications. The thresholds are
changed in Animal>VMS Cow>Automatic
diversion.
5
200
Timeout
filling
detergent
number %...f
User
notication
The configured amount of
detergent was not pumped to
charging vessel within time.
Cleaning is continued anyhow.
Make sure that there is detergent in the
container. Check that the hoses are
connected to the pump. If the problem
remains call a serviceman.
5
200
Timeout
filling
detergent
number %...f
User
notication
The configured amount of
detergent was not pumped to
charging vessel within time.
Cleaning is continued anyhow.
Make sure that there is detergent in the
container. Check that the hoses are
connected to the pump. If the problem
remains call a serviceman.
5
201
Timeout
filling water
in step %...f,
substep %...f
Stop alarm
Charge vessel was not filled within
time.
Note! If the charge vessel was not
empty when starting to fill water
this alarm could be generated at
start of filling.
Check water pressure, check filters or
strainers in the waterline! Check the water
valves! Make sure that the charge vessel is
empty before being refilled. Check the level
sensor. If the problem remains call a
serviceman.
5
201
Timeout
filling water
in step %...f,
substep %...f
Stop alarm
Charge vessel was not filled within
time.
Note! If the charge vessel was not
empty when starting to fill water
this alarm could be generated at
start of filling.
Check water pressure, check filters or
strainers in the waterline! Check the water
valves! Make sure that the charge vessel is
empty before being refilled. Check the level
sensor. If the problem remains call a
serviceman.
5
202
Timeout
empting
water in step
%.0f,
substep %.0f
Stop alarm
The water level in receiver does
not affect the upper level indicator
(EndUnitHighLevel is not reached),
when sucking water from washing
trough into receiver.
Check vacuum system, check connections
between all 5 teat cups and their jetters.
(Did you receive "teat cup not tight to jetter"
message?) If "EndUnitHighLevel" is
positioned too high, this alarm could be
generated. If the problem remains call a
serviceman.
5
202
Timeout
empting
water in step
%.0f,
substep %.0f
Stop alarm
The water level in receiver does
not affect the upper level indicator
(EndUnitHighLevel is not reached),
when sucking water from washing
trough into receiver.
Check vacuum system, check connections
between all 5 teat cups and their jetters.
(Did you receive "teat cup not tight to jetter"
message?) If "EndUnitHighLevel" is
positioned too high, this alarm could be
generated. If the problem remains call a
serviceman.
5
203
Too low
temp at
filling
%T.0%.0f
min
%T.0%.0f
Deviation
Water temperature at filling charge
vessel is too low.
Note this temperature check is only done
when using hot water. Check boiler, check
set point setting in cleaner configuration.
Check temperature sensor. If the problem
remains call a serviceman.
5
203
Too low
temp at
filling
%T.0%.0f
min
%T.0%.0f
Deviation
Water temperature at filling charge
vessel is too low.
Note this temperature check is only done
when using hot water. Check boiler, check
set point setting in cleaner configuration.
Check temperature sensor. If the problem
remains call a serviceman.
5
204
Too low
temp after
circulation
%T...%...f
min
%T...%...f
Deviation
The return water temperature is
measured at end of circulation
cleaning. If this temperature is
below limit set in cleaner
configuration the alarm will be
generated.
Check same at alarm 5:203. If the
installation has long not insulated transport
lines the temperature fall could be too big.
Check for residual pre-rinse water (purge
problem).
5
204
Too low
temp after
circulation
%T...%...f
min
%T...%...f
Deviation
The return water temperature is
measured at end of circulation
cleaning. If this temperature is
below limit set in cleaner
configuration the alarm will be
generated.
Check same at alarm 5:203. If the
installation has long not insulated transport
lines the temperature fall could be too big.
Check for residual pre-rinse water (purge
problem).
5
205
Invalid
cleaning
config.
Stop alarm
Cleaning procedure will not start.
Call for service engineer.
5
205
Invalid
cleaning
config.
Stop alarm
Cleaning procedure will not start.
Call for service engineer.
184(198)
Содержание VMS 2008
Страница 1: ...Instruction Book DeLaval voluntary milking system VMS model 2008 2007 12 18 0712 94897201 pdf ...
Страница 2: ......
Страница 10: ...94897201 pdf 2007 12 18 2 198 ...
Страница 144: ...Maintenance DeLaval voluntary milking system VMS 94897201 pdf 2007 12 18 136 198 ...
Страница 154: ...Maintenance Milk sampler 94897201 pdf 2007 12 18 146 198 ...
Страница 193: ...Troubleshooting DeLaval voluntary milking system VMS 94897201 pdf 2007 12 18 185 198 ...
Страница 206: ...DeLaval Box 39 SE 147 21 Tumba SWEDEN www delaval com ...