Maintenance
Milk sampler
94897201.pdf
2007-12-18
FG
2
Milk container
Disconnect hoses
2. Disconnect all hoses from the milk
container, then remove the container.
3. Use a syringe without a needle to clean
the disconnected hoses. Fill the syringe with
lukewarm water, press the tip of the syringe
into one of the hoses and then inject the
water through the hose. Repeat the same
procedure for all hoses.
If there are any dirt or milk residues left in
the hoses, remove the hoses and rinse
them with lukewarm water, then wash them
using a mild detergent, then rinse again with
water to remove detergent.
If the milk sampler has not been cleaned for
a long time, milk residues may be
impossible to remove, in which case the
tubes should be replaced. See the
additional maintenance below.
5. First disassemble the container, then
rinse it with lukewarm water and clean with
appropriate detergents. Finally, rinse again
with water to remove detergent.
6. Reconnect the hoses onto the container.
Note:
It is important not to shorten the
hoses too much if they have been
deteriorated.
FG
Cylindrical cone
on container lid
Clip
7. Reassemble the container. Note that the
cylindrical cones must face each other and
be properly inserted in the clip.
142(198)
Содержание VMS 2008
Страница 1: ...Instruction Book DeLaval voluntary milking system VMS model 2008 2007 12 18 0712 94897201 pdf ...
Страница 2: ......
Страница 10: ...94897201 pdf 2007 12 18 2 198 ...
Страница 144: ...Maintenance DeLaval voluntary milking system VMS 94897201 pdf 2007 12 18 136 198 ...
Страница 154: ...Maintenance Milk sampler 94897201 pdf 2007 12 18 146 198 ...
Страница 193: ...Troubleshooting DeLaval voluntary milking system VMS 94897201 pdf 2007 12 18 185 198 ...
Страница 206: ...DeLaval Box 39 SE 147 21 Tumba SWEDEN www delaval com ...