Troubleshooting
DeLaval in place ID reader IPR
1 Problems with the in-place
reader (IPR)
No.
Symptom
Cause
Action
1
Decreased reading distance. Disturbances caused by metal
objects placed near the reader.
n
Remove all metal objects
located within a distance of
less than 100 mm from the
sides or 500 mm at the front
of DeLaval in place ID
reader IPR.
n
Restart the reader.
2
The IPR reports unexpected
ID numbers.
More than one transponder in
the reading area.
Ensure a single transponder
reading and eliminate cross-
reading.
3
The IPR does not read any
transponders.
No power supply connected to
the DeLaval in place ID reader
IPR or wire issues.
n
Check the power supply.
n
Check the supply voltage
(12 or 24 V DC).
n
Contact an authorised
service technician.