11

Installation

Sleeve 12 x 60 

Screw TH M8 x 80

Washer 
Ø8.4 x 24

Ø12

80 mm “minimum”

Sleeve

Washer

Do not tighten the 

screws after the 

resistance point, you 

could damage the ins-

tallation. 

Concrete

Once the resistance 

point has been 

reached, turn the 

screws 3 times to 

finish the installation.

Washer

Concrete blocks

For concrete or panel pools and pools with a wall thicker than 8mm

Align the beam support 

with the separating wall

15 cm  

Max

Cover pit

Surface mounted model

Содержание RollEnergy Evolution

Страница 1: ......

Страница 2: ...ox Control box x1 Template Spare parts bag x1 x1 Anodised aluminium tube with tubular motor x8 Screw M8x80 x8 Sleeve 12 x4 Sleeve 8 x4 Screw M6x30 x15 Washer 8 4x24 x7 Nut M8 x1 Allen key n 4 Quick Lo...

Страница 3: ...am support 1 box of 0 30 x 0 20 x 0 20 m 10 Kg Decking 1 pallet of 1 20 x 1 00 x 0 50 m 100 Kg Slats 5 box of 0 25 x 0 20 x 5 00 m 250 Kg locking kit 1 box of 0 30 x 0 20 x 0 20 m or 0 75 x 0 25 x 0 1...

Страница 4: ...or the supports reinforcement Pool surface m x 2 5 x concrete litres Open pool the cover is in the cover pit under the decking The decking is supported by a beam installed on beam supports The depth o...

Страница 5: ...wall and the cover Tubular motor con form to electrical standards Decking Safety wall or S curiwall Control box conform to electrical standards C 15 100 NF EN 60335 NF EN 61000 6 3 NF EN 55014 1 slats...

Страница 6: ...cm back of the cover pit With radius and cut sides to 10 cm back of the cover pit water level regulator S curiwall S curiwall Main drain skimmer Minimum distance of the cover pit L Pool length step un...

Страница 7: ...ings If there is water in the pool put a support on the water Polystyrene plate to protect the water against dusts during the drilling TEMPLATE DRILLING 12 80 mm minimum Straight radius Radius or cut...

Страница 8: ...nish the installation Washer Concrete blocks Do not carry the tube with the motor s electrical cable If there is water in the pool let the tube fill in with water Motor side Do not forget the hole to...

Страница 9: ...ube so that the motor side is fitted properly against the wall Free side Tightening ring TUBE LEVEL ADJUSTMENT TUBE INSTALLATION ON THE SUPPORTS VERTICAL ADJUSTMENT ON THE TUBE POOL Adjustment cover p...

Страница 10: ...S For concrete pools Hanging support Washer 10 Screw inox A4 M10 x 60 Sleeve 12 Nut Inox A4 M10 12 Align the beam support with the separating wall 15 cm Max Cover pit Cover pit 15 cm Max Seal 1 Seal 2...

Страница 11: ...the resistance point you could damage the ins tallation Concrete Once the resistance point has been reached turn the screws 3 times to finish the installation Washer Concrete blocks For concrete or pa...

Страница 12: ...lats on the water and clip them together Take care with the direction of the cover over the pool For pools with a step unit Last slat of the step unit HOW TO TAKE OFF A SLAT AND END CAPS 69 mm slats w...

Страница 13: ...iddle telescopic support For pool over 6 m wide you need to install 1 or 2 middle telescopic support to maintain the beam Weights guarantee a better reeling of the cover around the tube and guide the...

Страница 14: ...14 5 cm ADJUSTMENT OF THE WEIGHT DEPTH Closed pool Open pool Adjust the depth of the weight I n s t a l l a t i o n...

Страница 15: ...15 Seal for wooden decking DECKING INSTALLATION I n s t a l l a t i o n...

Страница 16: ...must comply with the C15 100 standards last version Installation in a dry airy and moderate local Circuit breaker with a 30 mA protection 3 x 1 5 m m 2 x 4 m m u n t il 1 6 m 2 x 6 m m f r o m 1 6 u n...

Страница 17: ...ith the receiver The support must be attached to a fixed support Closing Opening Stops the current action Keyboard lock red green flashing emitter locked Emitter unlocking procedure see page 30 The em...

Страница 18: ...ion must comply with the C15 100 standards last version Installation in a dry airy and moderate local Circuit breaker with a 30 mA protection 3 x 1 5 m m 2 x 4 m m u n t il 1 6 m 2 x 6 m m f r o m 1 6...

Страница 19: ...1 Programme starting Adjust the position of the cover using the programme open and closed check up Cover installation open pool Cover opening Cover closing Contact maintained if the control logic is...

Страница 20: ...tment is over Recording position closed pool Adjust the position of the cover using the programme open and closed Be careful the last operation used must be a closing if you cannot close the cover che...

Страница 21: ...resistance during opennig the sotor is automatically stoppedt Cases of torque limiter activation Unreleased safety locking kit cover rudding coping stone Object wedged on under the cover cleaner Seri...

Страница 22: ...do not activate the torque limiter device serious damages might happen on the motor the electric control box the slats and the guarantee might not be applicable ADJUSTEMENT OF THE SENSITIVITY SWITCH P...

Страница 23: ...the end of Roman steps Without steps With Roman steps kit at the end of the steps Roman 2 kits at max 50 cm from the edge kit at max 50 cm from the edge 1 kit centred if 1 m 1 kit at 50 cm from the e...

Страница 24: ...crewing this would deteriorate the fixture quality Concrete After reaching the resistance point make 3 more turns of the screwdriver to finish tightening Concrete block Plug Washer Washer 5 cm 8 12 VB...

Страница 25: ...this would deteriorate the fixture quality Concrete After reaching the resistance point make 3 more turns of the screwdriver to finish tightening Washer Concrete block water level Acceptable limit of...

Страница 26: ...the resistance point make 3 more turns of the screwdriver to finish tightening Washer Concrete block 5 cm 5 cm 5 cm 8 water level Acceptable limit of level variation recommended water level Acceptabl...

Страница 27: ...ach surface Do not force the eyebolt into a drill hole of a smaller diameter than this Cruciform 4 x 25 Protective sheath single strap strap sheath staple loop Stretch the strap the cover must touch t...

Страница 28: ...29 I n s t a l l a t i o n...

Страница 29: ...tarting the motor Unlock all the fastening systems Operate the open control Stow the unlocking tools out of the reach of children Lock the WI Key command Closure Operate the contact maintained during...

Страница 30: ...RELEASING PUSH LOCK Locking Releasing Locking Releasing with tool check the system is locked with tool The cover must not exit the Quick Lock before you activate the key switch LOCKING AND RELEASING Q...

Страница 31: ...rap between the wall and the bracket Lock the anchor The strap must be under ten sion and must be through the bracket Release the anchor Remove the strap from around the bracket and put it on the cove...

Страница 32: ...r Closed the cover for more than 3 seconds until the tension of the cover is completely released closed the cover for more than 3 seconds until the tension of the cover is completely released Remove c...

Страница 33: ...hat the slats have not been visibly damaged in such as way as to affect the cover s operation slats with cracks holes deformations etc Change the slats or the whole cover if necessary In both summer a...

Страница 34: ...ashes green an emitter must be paired within the next 30 seconds Press STOP and without releasing it press O for more than 3 seconds OK when the pilot flashes red green another emitter must be paired...

Отзывы: