3
Total Eclipse
Installation & Operations Manual
c. The recommended location to plumb the Total Eclipse inlet
“T” is after the filter and before the heater.
NOTE: If returned directly to the skimmer, the ozonated water
will be drawn back into the filtration system and will not mix
with the pool water as effectively. If returned to the main return
line, the line pressure (back-pressure) could cause a loss
of suction and stop ozone from being mixed with the water,
causing large bubbles to be trapped and released into the pool
5. Ensure that the provided 5lb. check valve is installed at the
location and in the direction shown in the relevant figure.
NOTE: An installed check valve will not affect the Total Eclipse
if the check valve’s opening pressure is 1lb. or less.
6. In all cases the return should be in the pool bottom or as low as
possible on the pool wall.
7. When winterizing takes place, installation of the unions as
shown in Figures 1-4 is necessary. If no winterizing will take
place, unions are still included to facilitate unit removal if
necessary.
2B. Operation
Once the Total Eclipse has been properly installed, simply plug
the unit into a 120V / 240V G.F.C.I. protected outlet. Turn the main
pump on to its normal timed cycle. The Total Eclipse will detect flow
from the main pump and start automatically. The Total Eclipse will
continue running when the main pump cycles off. If water flow is
lost to the unit for any reason, the unit will shut down to protect the
internal pump. If power is lost, the unit will shut down until power
is restored to the main pump and the Total Eclipse. Once the main
pump cycles on, flow will be restored to the Total Eclipse and it will
begin running.
Indicator Lights: There are two lights, green and red, on the front
of the unit. The green light indicates when there is power to the unit
(when the unit’s power cord is plugged in to an electrical outlet). The
red light indicates when there is no water or ozone flow within the unit.
NOTE: When you initially plug in the Total Eclipse the red light
will be on. As soon as flow is initiated through the unit, via the