Total Eclipse
Installation & Operations Manual
2
NOTE: Exceeding the recommended elevations may affect the
water circulation rate (i.e. Total GPM/ozone delivery).
c. Even though the Total Eclipse is designed for outdoor use,
care should be taken when choosing a mounting location. To
protect your investment, mount the Total Eclipse where it is
protected from the elements (direct sun, rain, dirt), completely
sheltered if possible while providing adequate ventilation.
3. Install 3/4” PVC piping for circulation of pool water, as shown in
Figure 1.
a. Smaller diameter pipe will increase dynamic pressure loss,
possibly causing inefficient or faulty operation of the unit.
b. Pipe larger than 3/4” may be used if necessary. However, in
a larger diameter pipe larger air bubbles will collect, causing
gurgling at the pool. Avoid long pipe runs. Elbows, tees, and
sharp bends in the piping should be avoided when possible.
c. Plumbing an independent return line from the Total Eclipse
is highly recommended. Bubble formation and gurgling may
occur otherwise.
NOTE: Air bubbles in the system can be removed by installing
a DEL MDV-20. Contact your local dealer or visit DEL’s website
at www.delozone.com for details.
4. For optimum ozone distribution, the ozonated water should be
returned back to the pool through a dedicated pipe in the bottom
of the pool. If it is not possible to install with the dedicated return
to the bottom of the pool, then install the Total Eclipse as shown
in Figures 2, 3, or 4 based on the specific configuration of your
system. These installation figures cover the following installation
types: Figure 2–existing pools with in-floor cleaning system
(ICS); Figure 3–existing pool/spa combination without in-floor
cleaning system; Figure 4–existing pool/spa combination with
in-floor cleaning system.
In case you are building a new pool with an ICS or a new pool/spa
combination with or without an ICS follow these general guidelines:
a. Plumb the Water Inlet to the Total Eclipse as shown in
Figures 2, 3, and 4,
b. Plumb the Water Return out of the Total Eclipse as a
dedicated line to the bottom of the pool as shown in Figure 1.