DEL Clean Ozone Laundry Systems
Installation & Operations Manual
7
A1. Location
The Ozone Generator is designed for wall
mounting.
See Figure 5
. Mount generator in a
clean, protected area, either indoors or outdoors.
(See LOCATION REQUIREMENTS section 1B) It
can also be mounted to the fl oor or deck with
optional feet. (See REPLACEMENT PARTS section
5B) Locate generator out of reach of sprinklers or
drainage spouts. Allow suffi cient access for
maintenance and all tubing and electrical wires.
Ozone generator should be installed no less than
one foot above the maximum water level.
A1.1.
Mounting
A1.1.1. Wall Mount
A1.1.1.1.
Attach the Wall Mounting Brackets to
the base and top of the enclosure using the
four 1/4" x 1" long bolts and washers
provided.
A1.1.1.2.
Refer to Figure 5. Mark the
locations for the four mounting bolts and
install anchors appropriate for the mounting
surface.
A1.1.1.3.
Install the four mounting bolts through
the Wall Mounting Brackets and into the
anchors.
A1.1.2. Floor Mounting (optional)
The enclosure can be fl oor mounted to a solid,
fl at surface using the optional Floor Mounting Kit
Part
Number
9-5004.
A1.2.
Electrical
A1.2.1. Main power circuit:
The Ozone Generator
is supplied with a standard power cord. Plug
the cord into a standard 120V grounded,
grounding type receptacle only. NOTE:
The circuit must be protected by a ground-fault
circuit interrupter (GFCI) installed in accordance
with electrical codes. (A transformer is required
for export power requirements).
12.63
26.50
12.63
Figure 5: Wall Mount