DEL Clean Ozone Laundry Systems
Installation & Operations Manual
1
SECTION 1
General Information
1A. Description
The DEL Clean™ Ozone Laundry System described
in this manual is designed to provide the benefi ts of
ozonated water in an environmentally safe and
effective manner. DEL Clean™ generators are
National Sanitation Foundation (NSF) listed. The
high quality, specially engineered components
ensure effi cient ozone output and reliable
performance.
The DEL Clean™ Ozone Laundry System is safe
and harmless to your equipment if installed properly.
1B. Specifi cations
Ozone output (+10%)
0-7 g/hr
Flow rate (max):
7 scfh
% weight O
3
:
3 %
Power
Requirements:
Domestic:
120VAC, 60 Hz, 1Ø, 6.0 Amp
Shipping
Weight:
Approx. 61 pounds / 27.5 kg
Location
Requirements:
Mounting:
Wall mount in a clean, protected
area. Floor mounting kit
optional
.
Ambient
Temp:
40°F - 100°F (5°C - 40°C)
Ventilation:
Room should provide 6 air
changes per hour minimum.
Clearance:
Provide a minimum of 4" clearance
around unit.
Protection from weather elements must be
provided for outdoor installations. Operating
outside of the recommended temperature ranges
may result in damage not covered under the
manufacturer’s
warranty.
SECTION 2
Operation
2A. Initial System Start-Up
Upon completing all of the generator system
connections as outlined in the appendix, you are
ready to begin start up procedures.
1. Check plumbing fi ttings.
2. Check for proper voltage.
3. Start
Wash
Cycle.
4. Check for leaks.
5.
(CD-7GL-30 only)
With the ozone isolation valve
closed, adjust injector bypass valve to fl ow water
through the injector.
6. Open ozone isolation valve.
7. Plug Ozone Generator into electrical outlet.
8.
(CD-7G-11 only)
Verify that the “Ozone” light is on
by the time the washer gets to the “Low Fill” level.
Note:
(CD-7GL-30 only)
Your Injector Assembly is
equipped with a bypass valve, close the valve by
turning the handle clockwise until the proper suction
is indicated as described in Section 2B.
2B. Normal Operation
Once the Ozone Generator is plugged in and proper
suction is applied, the cooling fan, air compressor,
and oxygen concentrator will begin operating.
During the cold water fi ll the green 'Power' indicator
and green 'Ozone' indicator will be illuminated.
When the cold water fi ll cycle is completed, the red
'Vacuum' indicator will illuminate and the 'Ozone'
indicator will turn off.
Upon loss of suction the ozone will immediately shut
off and the generator will go into a timed shut down
mode. If proper suction is not reestablished within
the pre-set time (normally 10 minutes) the genera-
tor will go into stand-by mode. In stand-by mode, the
power and vacuum lights will be illuminated.
If the indicator lights are OK and the fl owmeter
is reading the proper fl ow (6-7 scfh)*, then the ozone
generator is producing ozone.
*Note: The CD-7G-11 will fl ow 10-20% less
Note:
Do not exceed the max fl ow rate specifi cation
as indicated in the specifi cation sticker.
If you experience complications see
TROUBLESHOOTING section 3D or contact DEL
technical
support
(See Section 3E)
.