Installation Instructions
1.
How the DEL Spa Ozone Generator Works
a.
DEL Ozone Generators produce ozone gas which is introduced to the spa
water through suction created by the spa. Tubing is used to connect the Ozone
Generator to an injector or a vacuum port provided by the spa manufacturer. The
injector or port are vacuum sources used to pull the ozone gas out of the Ozone
Generator and into the water.
At no time should water come in contact with
the Ozone Generator.
To protect the Ozone Generator from water traveling back-
wards through the tubing connection, the unit must be mounted and plumbed as
described in this manual.
2.
Installation Parts
a.
Common Installation Parts for ALL DEL Spa Ozone Generators
ONE Installation Manual – Ozone Generators for Spas (4-1223-01)
ONE check valve (7-1140-01)
FIVE feet of tubing (7-0075)
FOUR hose clamps (2-0078)
TWO screws (2-0078) for mounting
c.
Installation Parts specific to SpaEclipse
™
Dual Voltage
ONE Voltage Selector Switch Cover Label (4-1224-01)
d.
Installation Parts specific to ZO-300/302
ONE screw (2-0618) to connect lamp cartridge to ballast section
TWO metal spring mounting clips (8-0760)
e.
Installation Parts specific to Platinum
FOUR screws (2-0278) instead of the two screws included with the
SpaEclipse™, CDS-16 and ZO-300/302. Mount in any six of the mounting
holes (preferably two on top and two on bottom).
3.
Installation Tools and Materials
a.
Phillips Screwdriver
b.
Pliers
c.
Scissors
4.
Unit Assembly
a.
All models are pre-assembled and ready to install with the exception of
ZO-300 and ZO-302.
b.
Models ZO-300 and ZO-302:
Connecting ZO-300/302:
Insert lamp cartridge straight into power supply, being careful to align pins
and bonding plate (on back). Press power supply and lamp cartridge together.
4