background image

IMPORTANT SAFETY INSTRUCTIONS

Proper installation and usage of your DEL Spa Ozone Generator is your responsibility. Read 
and  follow  this  Owner’s  Manual  carefully  for  important  installation,  operation  and  safety  
information. Basic safety precautions should always be followed, including but not limited to 
the following:

1.    READ AND FOLLOW ALL INSTRUCTIONS.
2.    All electrical connections should be made by a qualified electrician. 
3.    Follow all applicable electrical codes.
4.    Be sure the electrical power is shut OFF at the main circuit breaker before installing the 
Ozone Generator.
5.    If the Ozone Generator electrical connection is to be attached to the spa controls, be sure 
the spa controls are protected by a Ground Fault Circuit Interrupter (G.F.C.I.). If the DEL Spa 
Ozone Generator is connected to an independent electrical supply, then a G.F.C.I. must be 
installed between the Ozone Generator and the electrical supply. 
6.    A pressure wire connector (ground lug) is provided on the outside of all ZO-300/301/302 
and Platinum ozone generator units to allow the connection of a minimum No. 8 AWG (8.4 
mm2) solid bonding conductor (wire) between this point and any metal equipment, metal 
enclosure of electrical equipment, metal water pipe or conduit within five (5) feet (1.5m) of the 
unit, as needed, to comply with local requirements.
7.    Do not bury cord. 
8.    WARNING - To reduce the risk of electrical shock, replace damaged cord immediately. 
9.    Per UL requirements, the Ozone Generator must be mounted indoors or under a cover, 
sheltered from natural elements (rain, sun, sprinklers).
10.  Mount the Ozone Generator so that it is inaccessible to anyone in the spa. Never attempt 
servicing when wet.
11.  To reduce the risk of injury, the unit should be mounted where it is inaccessible to children.
12.  Plastic ozone supply tubing is available with the Ozone Generator. Never replace this tubing  
with metal tubing.
13.  Do not operate the Ozone Generator unless sufficient air flow is being drawn through the 
unit (see Section 9c).
14.    WARNING:  Short  term  inhalation  of  high  concentrations  of  ozone  and  long-term  
inhalations of low concentrations of ozone can cause harmful physiological effects. Do not 
inhale ozone gas produced by the device.

SAVE THESE INSTRUCTIONS.

2

Содержание CDS-16

Страница 1: ...OZONE GENERATORS FOR SPAS INSTALLATION OPERATION MANUAL For Models SpaEclipse SpaEclipse Dual Voltage CDS 16 ZO 300 302 ZO 301 Platinum 4 1223 01 Rev B EPA Estab No 071472 CA 001...

Страница 2: ...nd Platinum ozone generator units to allow the connection of a minimum No 8 AWG 8 4 mm2 solid bonding conductor wire between this point and any metal equipment metal enclosure of electrical equipment...

Страница 3: ...lation Parts 4 3 Installation Tools and Materials 4 4 Unit Assembly 4 5 Mounting 6 6 Plumbing Vacuum System 6 7 Plumbing Ozone Generator 6 8 Electrical 7 9 Operation 7 10 Installation Complete 8 11 Ma...

Страница 4: ...1 ONE check valve 7 1140 01 FIVE feet of tubing 7 0075 FOUR hose clamps 2 0078 TWO screws 2 0078 for mounting c Installation Parts specific to SpaEclipse Dual Voltage ONE Voltage Selector Switch Cover...

Страница 5: ...te Lamp Cartridge Figure 1 Assembly of ZO 300 or ZO 302 Cartridge Figure 2 Ozone Generator Models CDS 16 SpaEclipse Dual Voltage ZO 300 302 ZO 301 Platinum Power Supply Bonding Plate Lamp Cartridge Oz...

Страница 6: ...her models use the mounting features provided on the Ozone Generator 6 Plumbing Vacuum System refer to Figure 4 a Most spas are factory equipped with an ozone injector or vacuum port like the one show...

Страница 7: ...age 9 Operation a With the spa filled to the proper level run the spa controller through several cycles b Verify that the Ozone Generator turns on and off as required by the controller i For the ZO 30...

Страница 8: ...e instruction sheet b In between Renewal Kit replacement years change the ozone check valve 7 1140 01 and Ozone Tubing 7 0075 c Although Platinum and ZO 301 do not have serviceable ozone components oz...

Страница 9: ...SYMPTOM The green LED not lit on Platinum No power to the ozonator Check the electrical connections and then the fuse PROBABLE CAUSE 1 Unit and pump not operating long enough 2 Total alkalinity not co...

Страница 10: ...WARRANTY OF MERCHANTABILITY OR IM PLIED WARRANTY OF FITNESS FOR PARTICULAR PURPOSE AND SUCH WAR RANTIES ARE HEREBY DISCLAIMED AND e DEL Ozone SHALL NOT BE LIA BLE UNDER ANY CIRCUMSTANCES FOR LOSS OF...

Страница 11: ..._____________________________Phone ________________ Dealer Address_______________________________________________________ City______________________________________State_________Zip__________ Purchase...

Страница 12: ...PO Box 4509 San Luis Obispo Ca 93401 800 676 1335 www delozone com...