A value, or set point, used to determine the controller's operation. Parameters include alarm settings, and the
configuration options for configurable inputs and outputs. The same set of parameters can be uploaded to
several controllers.

6.1.3 Units

The table below lists the units used in the documentation.

Unit

Name

Measures

A

ampere

Current

°C

degrees Celsius

Temperature

g

gram

Mass

H

hour

Time

kPa

kilopascal

Pressure

m

metre

Distance

mm

millimetre

Distance

ms

millisecond

Time

RPM

revolutions per minute

Speed

s

second

Time

V

volt

Voltage

V

ac

volt (alternating current)

Voltage (alternating current)

V

dc

volt (direct current)

Voltage (direct current)

W

watt

Power

Ω

ohm

Resistance

CGC 200 Operator's manual 4189340770
UK

Glossary

DEIF A/S

Page 43 of 43

Содержание CGC 200

Страница 1: ...K 7800 Skive Tel 45 9614 9614 Fax 45 9614 9615 info deif com www deif com 14 9614 Fax 45 9614 9615 info deif com www deif com OPERATOR S MANUAL Compact Genset Controller CGC 200 Push buttons LEDs and...

Страница 2: ...icons 10 2 4 5 Alarm icons 11 2 4 6 Display 11 3 Using the controller 3 1 Genset control mode and status 12 3 1 1 Genset control mode 12 3 1 2 Genset status 12 3 2 Basic tasks 12 3 2 1 Manual start 1...

Страница 3: ...ameters 35 5 3 2 Configuring inputs and outputs 36 5 3 3 Reading from the controller 37 5 3 4 Writing to the controller 38 5 3 5 Firmware upgrade 39 6 Glossary 6 1 Abbreviations and terms 41 6 1 1 Abb...

Страница 4: ...ator will also be able to monitor the system using the utility software 1 1 3 Revision information The letter at the end of the document number on the front page indicates the revision number of this...

Страница 5: ...tion All the product technical documentation is available on the DEIF website Training You can ask for training Support You can call or email DEIF DEIF offers 24 hour support There may also be a local...

Страница 6: ...if you need to remove the controller These precautions are no longer necessary once the controller is correctly installed and connected as re quired by the designer s wiring diagram 1 2 5 Legal infor...

Страница 7: ...re is a shutdown alarm Tests all the LEDs and the full LCD display if pressed for more than three seconds in Stop mode Changes the mode to Manual if in Auto mode Start Starts the engine Manual mode on...

Страница 8: ...tive non acknowledged alarm s present Mode OFF The unit is in manual mode RED STEADY The unit is in auto mode 2 4 Display 2 4 1 Display functions The display dimensions 20 mm x 40 mm shows readings an...

Страница 9: ...tal genset running hours 2 4 3 Alarms If an alarm is activated it is shown on the screen by the alarm icon See the examples below Example of over speed alarm Example of auxiliary alarm CGC 200 Operato...

Страница 10: ...tor voltage indication DC Battery voltage indication rpm Speed unit revolutions per minute kPa Oil pressure unit V Voltage unit Fuel level unit oC Temperature unit Hz Frequency unit H Accumulated runn...

Страница 11: ...der voltage Auxilliary alarm Low fuel level 2 4 6 Display The display is a backlit LCD text display containing lines with characters and icons The display light intensity can be adjusted by pressing f...

Страница 12: ...nformation on the genset statuses listed above 3 2 Basic tasks 3 2 1 Manual start To start the genset manually 1 Ensure that the controller is in Manual mode If the controller is in Auto mode the LED...

Страница 13: ...3 2 7 Adjusting and testing the display The display light intensity can be adjusted by pressing for more than five seconds Keep pressing until the light level 0 to 7 is right for you 0 corresponds to...

Страница 14: ...ters should not be changed without first consulting qualified and experi enced persons For more information about the controller functions and sequences that the parameters are based on see the Design...

Страница 15: ...0 s 0 Timer for idle speed after starting P08 GB close delay 3 to 3600 s 10 Timer for generator breaker close after frequency and voltage OK P09 Cooldown time 3 to 3600 s 10 Cooling down time P10 Idle...

Страница 16: ...6 4 See Table 1 Configurable output func tions P26 Relay 02 0 to 6 1 P27 Relay 03 0 to 6 2 P28 Digital input 1 0 to 10 5 See Table 2 Configurable input func tions P29 Digital input 1 timer 0 to 20 0...

Страница 17: ...genset fre quency see P42 For RPM P13 and P41 must be de fined For frequency P42 must be defined P41 Remove starter RPM 0 to 3000 RPM 360 Minimum engine speed required for re moval of the starter and...

Страница 18: ...Running minutes offset 0 to 59 mi nutes 0 Additional offset for the genset s running time timer 48 Running seconds offset 0 to 59 s 0 Additional offset for the genset s running time timer 49 Start att...

Страница 19: ...ory default code is 2000 To enter the access code 1 Press to increase the value of the digit where the cursor is blinking You can use to de crease the value 2 Press to move to the next digit 3 When th...

Страница 20: ...and PAGE DOWN together Enter parameter setting mode AUTO Increase value or next parameter ON Decrease value or previous parameter PAGE DOWN Next or Enter OFF Exit CGC 200 Operator s manual 4189340770...

Страница 21: ...installed Microsoft Windows creates an incorrect USB driver if the controller is connected before the software is installed If you have this problem you need to find the correct USB driver in the sof...

Страница 22: ...3 Click Software download on the left side of the page CGC 200 Operator s manual 4189340770 UK Using the Utility Software DEIF A S Page 22 of 43...

Страница 23: ...Utility Software v 3 x from the drop down list A dialogue box opens with information about the most recent version of the software CGC 200 Operator s manual 4189340770 UK Using the Utility Software D...

Страница 24: ...oading the software choose Run An installation wizard opens 2 Use the suggested default settings Note Option N refers to a TCP IP connection and is not relevant for CGC 200 3 When the installation is...

Страница 25: ...he Settings icon on the toolbar 3 Under Communication in the Communication type field select Service port The other communica tion types are not relevant for CGC 200 4 In the Communication port drop d...

Страница 26: ...t have a CGC 200 connected to your PC in order to see the Device Alarms Trending Parameters and Inputs Outputs pages CGC 200 Operator s manual 4189340770 UK Using the Utility Software DEIF A S Page 26...

Страница 27: ...tory Trending Real time trending of measured values Parameters View and edit parameters configure inputs and outputs and set de lays and timers in Tree and List view modes Inputs Outputs Status of dig...

Страница 28: ...lity Software Change or View the permission level Open a Utility Software or project file Print Print preview Settings Write firmware to the controller Batch read or write parameters to the controller...

Страница 29: ...ion is shown Engine speed RPM Generator voltage Generator frequency Battery voltage Start attempts Running hours minutes and seconds Genset mode Auto or Manual and current status Standby Crank Fuel on...

Страница 30: ...alarm on the Alarms page See the following screenshot for an example 5 2 4 Trending page You can see the real time trends for operating data on the Trending page See the following screenshot for an ex...

Страница 31: ...To start real time trends 1 Open the Trending page CGC 200 Operator s manual 4189340770 UK Using the Utility Software DEIF A S Page 31 of 43...

Страница 32: ...example is shown below 3 To set how often the trend updates as well as the trend width and memory select File then Settings then the Trending tab Set the values you want and click OK An example is sho...

Страница 33: ...view the parameters are listed in groups as shown below Click on the group name to display all the parameters in that group You can edit the parameters using the sliders selectable text and values bo...

Страница 34: ...om that in the controller For example you may have made a change and did not write the new value to the controller The change will not be updated in the controller until you write it to the controller...

Страница 35: ...option In Tree view change the parameter by selecting the option you want from the drop down list In List view double click the parameter line you want to change A dialogue box containing the drop do...

Страница 36: ...ion about how to write the changed values to the CGC 200 5 3 2 Configuring inputs and outputs Digital inputs and outputs can be configured in either Tree or List view In Tree view select the input or...

Страница 37: ...the CGC 200 This information can also be stored in a file on the PC You can read from the controller by Connecting to the controller the utility software automatically reads the information in the CG...

Страница 38: ...on the toolbar and select Read from device 2 The Batch job Reading dialogue box opens Select the information that you would like to read using the check boxes and click Run 3 A window opens Browse to...

Страница 39: ...ribed below Restoring the controller information from a bak file using Restore Device Batch write function If a CGC 200 file has been saved on the PC it can be opened edited and then written to one or...

Страница 40: ...he firmware file you want to use 3 Click Open Do not disconnect the power supply or the USB cable during the firmware upgrade Interrupt ing a firmware upgrade can make the controller unusable CGC 200...

Страница 41: ...ouncil for Standardization Metrology and Certification IEC International Electrotechnical Commission IP Ingress Protection Rating or International Protection Rating The degree of protection against so...

Страница 42: ...refers to the average AC voltage t Time U Voltage U is typically used as an abbreviation for voltage in Europe In other countries V may be used instead Unom Nominal voltage U is typically used as an a...

Страница 43: ...nits used in the documentation Unit Name Measures A ampere Current C degrees Celsius Temperature g gram Mass H hour Time kPa kilopascal Pressure m metre Distance mm millimetre Distance ms millisecond...

Отзывы: