![Dehler D44 Скачать руководство пользователя страница 45](http://html.mh-extra.com/html/dehler/d44/d44_owners-manual_2465042045.webp)
Yacht Manual Dehler 44
45 - 68
Important Note
Every two years you must comply with the obligatory inspections in accordance with
Regulation G 608 and ask the technician for a certificate.
Do not use solutions containing ammonium for checking the pipe.
Never use a naked flame to search for a leak.
Do not smoke and do not use a naked flame when connecting up or replacing a gas bottle
Appendix concerning the gas installation
If a marine vessel is equipped with a liquid gas installation, instruction for operating and servicing the
installation must be contained in the manual for the ship operator in accordance with ISO 10240, including
instructions from the manufacturer of the unit, amongst other information the following from C2 through C13:
C2
Close the valves of the supply line and the bottles when the units are not in operation. In case of an emergency,
always immediately close the valves.
C3
Be sure that the installation’s valves are clsoed before opening the bottle’s valve.
C4
Inspect the liquid gas installation regularly for possible leaks. Check all connections by:
-
routinely inspecting a bubble leak detector (if there is a detector present)
-
inspecting the overpressure measurement unit for a pressure drop, with the valves of the installation
being closed and the bottle valve open, then closed (if there is a measurement unit on the supply
pressure side)
-
using a manually operated leak seeker, or
-
using soapy water or cleaning agent. (Keep the installation’s valves closed and the bottle and unit
valves open).
If you find any leaks, close the bottle valve and have the installation repaired before using it again. The repair of
the installation must be carried out by a professional.
CAUTION Use no solutions that contain ammonia.
ATTENTION Never work with open flame to seek leaks.
C5
ATTENTION When burning fuel with an open flame, the units use oxygen, and incineration residual is left
behind in the vessel. Therefore be sure there is ventilation while operating the unit. Never use either the cooker
nor the oven to heat the room. Never close the ventilation openings. The boat builder must make specifications
regarding the type and location of relevant ventilation openings of living spaces containing installations.
C6
Never lock the access to parts of the liquid gas installation.
C7
See to it that the valves of empty gas bottles are closed and disconnected from the installation. Keep covers, caps
or plugs within easy access. Stow spare bottles in ventilated bottle cupboards on the open deck or in special gas-
tight cupboards that are ventilated by outside air.
C8
Never use the gas bottle cupboard or locker to store other equipment.
Содержание D44
Страница 2: ...Yacht Manual Dehler 44 2 68 Manual version 02 01 07 Your Distributor s Stamp ...
Страница 32: ...Yacht Manual Dehler 44 32 68 ...
Страница 33: ...Yacht Manual Dehler 44 33 68 ...